Towards a black-box for biological EXAFS data analysis. II. Automatic BioXAS Refinement and Analysis (ABRA)

In biological systems, X-ray absorption spectroscopy (XAS) can determine structural details of metal binding sites with high resolution. Here a method enabling an automated analysis of the corresponding EXAFS data is presented, utilizing in addition to least-squares refinement the prior knowledge ab...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Journal of synchrotron radiation. - 1994. - 17(2010), 1 vom: 19. Jan., Seite 25-35
1. Verfasser: Wellenreuther, Gerd (VerfasserIn)
Weitere Verfasser: Parthasarathy, Venkataraman, Meyer-Klaucke, Wolfram
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2010
Zugriff auf das übergeordnete Werk:Journal of synchrotron radiation
Schlagworte:Journal Article Research Support, Non-U.S. Gov't Biopolymers Metalloproteins Metals
LEADER 01000caa a22002652c 4500
001 NLM193932105
003 DE-627
005 20250211034821.0
007 cr uuu---uuuuu
008 231223s2010 xx |||||o 00| ||eng c
024 7 |a 10.1107/S0909049509040576  |2 doi 
028 5 2 |a pubmed25n0646.xml 
035 |a (DE-627)NLM193932105 
035 |a (NLM)20029108 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Wellenreuther, Gerd  |e verfasserin  |4 aut 
245 1 0 |a Towards a black-box for biological EXAFS data analysis. II. Automatic BioXAS Refinement and Analysis (ABRA) 
264 1 |c 2010 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 10.03.2010 
500 |a Date Revised 01.10.2010 
500 |a published: Print-Electronic 
500 |a Citation Status MEDLINE 
520 |a In biological systems, X-ray absorption spectroscopy (XAS) can determine structural details of metal binding sites with high resolution. Here a method enabling an automated analysis of the corresponding EXAFS data is presented, utilizing in addition to least-squares refinement the prior knowledge about structural details and important fit parameters. A metal binding motif is characterized by the type of donor atoms and their bond lengths. These fit results are compared by bond valance sum analysis and target distances with established structures of metal binding sites. Other parameters such as the Debye-Waller factor and shift of the Fermi energy provide further insights into the quality of a fit. The introduction of mathematical criteria, their combination and calibration allows an automated analysis of XAS data as demonstrated for a number of examples. This presents a starting point for future applications to all kinds of systems studied by XAS and allows the algorithm to be transferred to data analysis in other fields 
650 4 |a Journal Article 
650 4 |a Research Support, Non-U.S. Gov't 
650 7 |a Biopolymers  |2 NLM 
650 7 |a Metalloproteins  |2 NLM 
650 7 |a Metals  |2 NLM 
700 1 |a Parthasarathy, Venkataraman  |e verfasserin  |4 aut 
700 1 |a Meyer-Klaucke, Wolfram  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Journal of synchrotron radiation  |d 1994  |g 17(2010), 1 vom: 19. Jan., Seite 25-35  |w (DE-627)NLM09824129X  |x 1600-5775  |7 nnas 
773 1 8 |g volume:17  |g year:2010  |g number:1  |g day:19  |g month:01  |g pages:25-35 
856 4 0 |u http://dx.doi.org/10.1107/S0909049509040576  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_40 
912 |a GBV_ILN_350 
912 |a GBV_ILN_2005 
951 |a AR 
952 |d 17  |j 2010  |e 1  |b 19  |c 01  |h 25-35