Toward a real-time simulation of ultrasound image sequences based on a 3-D set of moving scatterers

Data simulation is an important research tool to evaluate algorithms. Two types of methods are currently used to simulate medical ultrasound data: those based on acoustic models and those based on convolution models. The simulation of ultrasound data sequences is very time-consuming. In addition, ma...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on ultrasonics, ferroelectrics, and frequency control. - 1986. - 56(2009), 10 vom: 01. Okt., Seite 2167-79
1. Verfasser: Marion, Adrien (VerfasserIn)
Weitere Verfasser: Vray, Didier
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2009
Zugriff auf das übergeordnete Werk:IEEE transactions on ultrasonics, ferroelectrics, and frequency control
Schlagworte:Journal Article Research Support, Non-U.S. Gov't
LEADER 01000naa a22002652 4500
001 NLM193097281
003 DE-627
005 20231223194136.0
007 cr uuu---uuuuu
008 231223s2009 xx |||||o 00| ||eng c
024 7 |a 10.1109/TUFFC.2009.1299  |2 doi 
028 5 2 |a pubmed24n0644.xml 
035 |a (DE-627)NLM193097281 
035 |a (NLM)19942504 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Marion, Adrien  |e verfasserin  |4 aut 
245 1 0 |a Toward a real-time simulation of ultrasound image sequences based on a 3-D set of moving scatterers 
264 1 |c 2009 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 28.01.2010 
500 |a Date Revised 27.11.2009 
500 |a published: Print 
500 |a Citation Status MEDLINE 
520 |a Data simulation is an important research tool to evaluate algorithms. Two types of methods are currently used to simulate medical ultrasound data: those based on acoustic models and those based on convolution models. The simulation of ultrasound data sequences is very time-consuming. In addition, many applications require accounting for the out-of-plane motion induced by the 3-D displacement of scatterers. The purpose of this paper is to propose a model adapted to a fast simulation of ultrasonic data sequences with 3-D moving scatterers. Our approach is based on the convolution model. The scatterers are moved in a 3-D continuous medium between each pair of images and then projected onto the imaging plane before being convolved. This paper discusses the practical implementation of the convolution that can be performed directly or after a grid approximation. The grid approximation convolution is obviously faster than the direct convolution but generates errors resulting from the approximation to the grid's nodes. We provide the analytical expression of these errors and then define 2 intensity-based criteria to quantify them as a function of the spatial sampling. The simulation of an image requires less than 2 s with oversampling, thus reducing these errors. The simulation model is validated with first- and second-order statistics. The positions of the scatterers at each imaging time can be provided by a displacement model. An example applied to flow imaging is proposed. Several cases are used to show that this displacement model provides realistic data. It is validated with speckle tracking, a well-known motion estimator in ultrasound imaging 
650 4 |a Journal Article 
650 4 |a Research Support, Non-U.S. Gov't 
700 1 |a Vray, Didier  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t IEEE transactions on ultrasonics, ferroelectrics, and frequency control  |d 1986  |g 56(2009), 10 vom: 01. Okt., Seite 2167-79  |w (DE-627)NLM098181017  |x 1525-8955  |7 nnns 
773 1 8 |g volume:56  |g year:2009  |g number:10  |g day:01  |g month:10  |g pages:2167-79 
856 4 0 |u http://dx.doi.org/10.1109/TUFFC.2009.1299  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_22 
912 |a GBV_ILN_24 
912 |a GBV_ILN_350 
951 |a AR 
952 |d 56  |j 2009  |e 10  |b 01  |c 10  |h 2167-79