Real-time fault detection and isolation in biological wastewater treatment plants

Automatic fault detection is becoming increasingly important in wastewater treatment plant operation, given the stringent treatment standards and the need to protect the investment costs from the potential damage of an unchecked fault propagating through the plant. This paper describes the developme...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Water science and technology : a journal of the International Association on Water Pollution Research. - 1986. - 60(2009), 11 vom: 24., Seite 2949-61
1. Verfasser: Baggiani, F (VerfasserIn)
Weitere Verfasser: Marsili-Libelli, S
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2009
Zugriff auf das übergeordnete Werk:Water science and technology : a journal of the International Association on Water Pollution Research
Schlagworte:Journal Article
LEADER 01000naa a22002652 4500
001 NLM193025566
003 DE-627
005 20231223194023.0
007 cr uuu---uuuuu
008 231223s2009 xx |||||o 00| ||eng c
024 7 |a 10.2166/wst.2009.723  |2 doi 
028 5 2 |a pubmed24n0643.xml 
035 |a (DE-627)NLM193025566 
035 |a (NLM)19934517 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Baggiani, F  |e verfasserin  |4 aut 
245 1 0 |a Real-time fault detection and isolation in biological wastewater treatment plants 
264 1 |c 2009 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 30.04.2010 
500 |a Date Revised 25.11.2009 
500 |a published: Print 
500 |a Citation Status MEDLINE 
520 |a Automatic fault detection is becoming increasingly important in wastewater treatment plant operation, given the stringent treatment standards and the need to protect the investment costs from the potential damage of an unchecked fault propagating through the plant. This paper describes the development of a real-time Fault Detection and Isolation (FDI) system based on an adaptive Principal Component Analysis (PCA) algorithm, used to compare the current plant operation with a correct performance model based on a reference data set and the output of three ion-specific sensors (Hach-Lange gmbh, Düsseldorf, Germany): two Nitratax NOx UV sensors, in the denitrification tank and downstream of the oxidation tanks, where an Amtax ammonium-N sensor was also installed. The algorithm was initially developed in the Matlab environment and then ported into the LabView 8.20 (National Instruments, Austin, TX, USA) platform for real-time operation using a compact Field Point, a Programmable Automation Controller by National Instruments. The FDI was tested with a large set of operational data with 1 min sampling time from August 2007 through May 2008 from a full-scale plant. After describing the real-time version of the PCA algorithm, this was tested with nine months of operational data which were sequentially processes by the algorithm in order to simulate an on-line operation. The FDI performance was assessed by organizing the sequential data in two differing moving windows: a short-horizon window to test the response to single malfunctions and a longer time-horizon to simulate multiple unrepaired failures. In both cases the algorithm performance was very satisfactory, with a 100% failure detection in the short window case, which decreased to 84% in the long window setting. The short-window performance was very effective in isolating sensor failures and short duration disturbances such as spikes, whereas the long term horizon provided accurate detection of long-term drifts and proved robust enough to allow for some delay in failure recovery. The system robustness is based on the use of multiple statistics which proved instrumental in discriminating among the various causes of malfunctioning 
650 4 |a Journal Article 
700 1 |a Marsili-Libelli, S  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Water science and technology : a journal of the International Association on Water Pollution Research  |d 1986  |g 60(2009), 11 vom: 24., Seite 2949-61  |w (DE-627)NLM098149431  |x 0273-1223  |7 nnns 
773 1 8 |g volume:60  |g year:2009  |g number:11  |g day:24  |g pages:2949-61 
856 4 0 |u http://dx.doi.org/10.2166/wst.2009.723  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_350 
951 |a AR 
952 |d 60  |j 2009  |e 11  |b 24  |h 2949-61