A combination of a Drickamer anvil apparatus and monochromatic X-rays for stress and strain measurements under high pressure

A modified Drickamer anvil apparatus has been developed to combine with monochromatic synchrotron radiation for high-pressure X-ray diffraction and radiography in the GSECARS bending-magnet station, 13-BM-D, at the Advanced Photon Source, Argonne, USA. Using this experimental set-up, deformation exp...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Journal of synchrotron radiation. - 1994. - 16(2009), Pt 6 vom: 18. Nov., Seite 742-7
1. Verfasser: Nishiyama, Norimasa (VerfasserIn)
Weitere Verfasser: Wang, Yanbin, Irifune, Tetsuo, Sanehira, Takeshi, Rivers, Mark L, Sutton, Steve R, Cookson, David
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2009
Zugriff auf das übergeordnete Werk:Journal of synchrotron radiation
Schlagworte:Journal Article Research Support, Non-U.S. Gov't Research Support, U.S. Gov't, Non-P.H.S.
LEADER 01000caa a22002652 4500
001 NLM192189948
003 DE-627
005 20250210220247.0
007 cr uuu---uuuuu
008 231223s2009 xx |||||o 00| ||eng c
024 7 |a 10.1107/S0909049509033342  |2 doi 
028 5 2 |a pubmed25n0641.xml 
035 |a (DE-627)NLM192189948 
035 |a (NLM)19844008 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Nishiyama, Norimasa  |e verfasserin  |4 aut 
245 1 2 |a A combination of a Drickamer anvil apparatus and monochromatic X-rays for stress and strain measurements under high pressure 
264 1 |c 2009 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 05.01.2010 
500 |a Date Revised 21.10.2009 
500 |a published: Print-Electronic 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a A modified Drickamer anvil apparatus has been developed to combine with monochromatic synchrotron radiation for high-pressure X-ray diffraction and radiography in the GSECARS bending-magnet station, 13-BM-D, at the Advanced Photon Source, Argonne, USA. Using this experimental set-up, deformation experiments can be carried out at pressures in excess of 30 GPa at high temperatures. Differential stresses and total axial strains of polycrystalline platinum and Mg(2)SiO(4) ringwoodite have been measured up to 32 GPa at room temperature using tungsten carbide anvils. The total axial strain of the platinum increases with pressure and reaches about 55% at the highest pressure. A test run using a composite sintered diamond anvil system was performed. The use of X-ray-tranparent anvils enables the entire Debye rings to be observed up to 10 degrees 2theta. With high-energy photons (65-70 keV), this allows a coverage in Q (= 2pi sintheta/lambda) to about 3 A(-1), thus making it possible to evaluate hydrostatic pressure and differential stress in crystalline minerals using diffraction. This, coupled with the ability to determine axial strain, allows deformation studies to be performed to pressures above 30 GPa 
650 4 |a Journal Article 
650 4 |a Research Support, Non-U.S. Gov't 
650 4 |a Research Support, U.S. Gov't, Non-P.H.S. 
700 1 |a Wang, Yanbin  |e verfasserin  |4 aut 
700 1 |a Irifune, Tetsuo  |e verfasserin  |4 aut 
700 1 |a Sanehira, Takeshi  |e verfasserin  |4 aut 
700 1 |a Rivers, Mark L  |e verfasserin  |4 aut 
700 1 |a Sutton, Steve R  |e verfasserin  |4 aut 
700 1 |a Cookson, David  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Journal of synchrotron radiation  |d 1994  |g 16(2009), Pt 6 vom: 18. Nov., Seite 742-7  |w (DE-627)NLM09824129X  |x 1600-5775  |7 nnns 
773 1 8 |g volume:16  |g year:2009  |g number:Pt 6  |g day:18  |g month:11  |g pages:742-7 
856 4 0 |u http://dx.doi.org/10.1107/S0909049509033342  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_40 
912 |a GBV_ILN_350 
912 |a GBV_ILN_2005 
951 |a AR 
952 |d 16  |j 2009  |e Pt 6  |b 18  |c 11  |h 742-7