Reduction of the damping on an AFM cantilever in fluid by the use of micropillars

In single molecule force measurements with soft atomic force microscope (AFM) cantilevers, the force sensitivity is limited by the Brownian motion of the cantilever. When a cantilever is close to the surface, the hydrodynamic interaction between the cantilever beam and the surface, called the "...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Langmuir : the ACS journal of surfaces and colloids. - 1992. - 26(2010), 2 vom: 19. Jan., Seite 1002-7
1. Verfasser: Kawakami, Masaru (VerfasserIn)
Weitere Verfasser: Taniguchi, Yukinori, Hiratsuka, Yuichi, Shimoike, Masahiko, Smith, D Alastair
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2010
Zugriff auf das übergeordnete Werk:Langmuir : the ACS journal of surfaces and colloids
Schlagworte:Journal Article Research Support, Non-U.S. Gov't
LEADER 01000naa a22002652 4500
001 NLM191651036
003 DE-627
005 20231223191611.0
007 cr uuu---uuuuu
008 231223s2010 xx |||||o 00| ||eng c
024 7 |a 10.1021/la902472h  |2 doi 
028 5 2 |a pubmed24n0639.xml 
035 |a (DE-627)NLM191651036 
035 |a (NLM)19785459 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Kawakami, Masaru  |e verfasserin  |4 aut 
245 1 0 |a Reduction of the damping on an AFM cantilever in fluid by the use of micropillars 
264 1 |c 2010 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 11.03.2010 
500 |a Date Revised 13.01.2010 
500 |a published: Print 
500 |a Citation Status MEDLINE 
520 |a In single molecule force measurements with soft atomic force microscope (AFM) cantilevers, the force sensitivity is limited by the Brownian motion of the cantilever. When a cantilever is close to the surface, the hydrodynamic interaction between the cantilever beam and the surface, called the "squeezing effect", becomes significant, and the resonance peak of the thermal oscillation of the cantilever is heavily broadened and shifted to lower frequency which makes it difficult to eliminate the thermal noise by low-pass filtering. In this study, we propose an easy and low-cost method to improve the force sensitivity. We demonstrate that by bringing a tip of a cantilever onto the edge of a micropillar structure a significant reduction of the damping and an enhancement of force sensitivity are achieved 
650 4 |a Journal Article 
650 4 |a Research Support, Non-U.S. Gov't 
700 1 |a Taniguchi, Yukinori  |e verfasserin  |4 aut 
700 1 |a Hiratsuka, Yuichi  |e verfasserin  |4 aut 
700 1 |a Shimoike, Masahiko  |e verfasserin  |4 aut 
700 1 |a Smith, D Alastair  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Langmuir : the ACS journal of surfaces and colloids  |d 1992  |g 26(2010), 2 vom: 19. Jan., Seite 1002-7  |w (DE-627)NLM098181009  |x 1520-5827  |7 nnns 
773 1 8 |g volume:26  |g year:2010  |g number:2  |g day:19  |g month:01  |g pages:1002-7 
856 4 0 |u http://dx.doi.org/10.1021/la902472h  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_22 
912 |a GBV_ILN_350 
912 |a GBV_ILN_721 
951 |a AR 
952 |d 26  |j 2010  |e 2  |b 19  |c 01  |h 1002-7