Fast two-dimensional detection for X-ray photon correlation spectroscopy using the PILATUS detector

The first X-ray photon correlation spectroscopy experiments using the fast single-photon-counting detector PILATUS (Paul Scherrer Institut, Switzerland) have been performed. The short readout time of this detector permits access to intensity autocorrelation functions describing dynamics in the milli...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Journal of synchrotron radiation. - 1994. - 16(2009), Pt 5 vom: 23. Sept., Seite 687-9
1. Verfasser: Westermeier, Fabian (VerfasserIn)
Weitere Verfasser: Autenrieth, Tina, Gutt, Christian, Leupold, Olaf, Duri, Agnes, Menzel, Andreas, Johnson, Ian, Broennimann, Christian, Grübel, Gerhard
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2009
Zugriff auf das übergeordnete Werk:Journal of synchrotron radiation
Schlagworte:Journal Article
LEADER 01000caa a22002652c 4500
001 NLM190981717
003 DE-627
005 20250210175220.0
007 cr uuu---uuuuu
008 231223s2009 xx |||||o 00| ||eng c
024 7 |a 10.1107/S0909049509023280  |2 doi 
028 5 2 |a pubmed25n0637.xml 
035 |a (DE-627)NLM190981717 
035 |a (NLM)19713644 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Westermeier, Fabian  |e verfasserin  |4 aut 
245 1 0 |a Fast two-dimensional detection for X-ray photon correlation spectroscopy using the PILATUS detector 
264 1 |c 2009 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 02.11.2009 
500 |a Date Revised 28.08.2009 
500 |a published: Print-Electronic 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a The first X-ray photon correlation spectroscopy experiments using the fast single-photon-counting detector PILATUS (Paul Scherrer Institut, Switzerland) have been performed. The short readout time of this detector permits access to intensity autocorrelation functions describing dynamics in the millisecond range that are difficult to access with charge-coupled device detectors with typical readout times of several seconds. Showing no readout noise the PILATUS detector enables measurements of samples that either display fast dynamics or possess only low scattering power with an unprecedented signal-to-noise ratio 
650 4 |a Journal Article 
700 1 |a Autenrieth, Tina  |e verfasserin  |4 aut 
700 1 |a Gutt, Christian  |e verfasserin  |4 aut 
700 1 |a Leupold, Olaf  |e verfasserin  |4 aut 
700 1 |a Duri, Agnes  |e verfasserin  |4 aut 
700 1 |a Menzel, Andreas  |e verfasserin  |4 aut 
700 1 |a Johnson, Ian  |e verfasserin  |4 aut 
700 1 |a Broennimann, Christian  |e verfasserin  |4 aut 
700 1 |a Grübel, Gerhard  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Journal of synchrotron radiation  |d 1994  |g 16(2009), Pt 5 vom: 23. Sept., Seite 687-9  |w (DE-627)NLM09824129X  |x 1600-5775  |7 nnas 
773 1 8 |g volume:16  |g year:2009  |g number:Pt 5  |g day:23  |g month:09  |g pages:687-9 
856 4 0 |u http://dx.doi.org/10.1107/S0909049509023280  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_40 
912 |a GBV_ILN_350 
912 |a GBV_ILN_2005 
951 |a AR 
952 |d 16  |j 2009  |e Pt 5  |b 23  |c 09  |h 687-9