Soft X-ray characterization technique for Li batteries under operating conditions

O K-edge and Co L-edge near-edge X-ray absorption fine structure has been used to examine the cathode of an intact solid-state lithium ion battery. The novel technique allowed for the simultaneous acquisition of partial electron yield and fluorescence yield data during the first charge cycle of a Li...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Journal of synchrotron radiation. - 1994. - 16(2009), Pt 5 vom: 23. Sept., Seite 610-5
1. Verfasser: Petersburg, Cole F (VerfasserIn)
Weitere Verfasser: Daniel, Robert C, Jaye, Cherno, Fischer, Daniel A, Alamgir, Faisal M
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2009
Zugriff auf das übergeordnete Werk:Journal of synchrotron radiation
Schlagworte:Journal Article
LEADER 01000caa a22002652 4500
001 NLM190981601
003 DE-627
005 20250210175219.0
007 cr uuu---uuuuu
008 231223s2009 xx |||||o 00| ||eng c
024 7 |a 10.1107/S0909049509025710  |2 doi 
028 5 2 |a pubmed25n0637.xml 
035 |a (DE-627)NLM190981601 
035 |a (NLM)19713633 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Petersburg, Cole F  |e verfasserin  |4 aut 
245 1 0 |a Soft X-ray characterization technique for Li batteries under operating conditions 
264 1 |c 2009 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 02.11.2009 
500 |a Date Revised 28.08.2009 
500 |a published: Print-Electronic 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a O K-edge and Co L-edge near-edge X-ray absorption fine structure has been used to examine the cathode of an intact solid-state lithium ion battery. The novel technique allowed for the simultaneous acquisition of partial electron yield and fluorescence yield data during the first charge cycle of a LiCoO(2)-based battery below the intercalation voltage. The chemical environments of oxygen and cobalt at the surface are shown to differ chemically from those in the bulk. The present design enables a wide variety of in situ spectroscopies, microscopies and scattering techniques 
650 4 |a Journal Article 
700 1 |a Daniel, Robert C  |e verfasserin  |4 aut 
700 1 |a Jaye, Cherno  |e verfasserin  |4 aut 
700 1 |a Fischer, Daniel A  |e verfasserin  |4 aut 
700 1 |a Alamgir, Faisal M  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Journal of synchrotron radiation  |d 1994  |g 16(2009), Pt 5 vom: 23. Sept., Seite 610-5  |w (DE-627)NLM09824129X  |x 1600-5775  |7 nnns 
773 1 8 |g volume:16  |g year:2009  |g number:Pt 5  |g day:23  |g month:09  |g pages:610-5 
856 4 0 |u http://dx.doi.org/10.1107/S0909049509025710  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_40 
912 |a GBV_ILN_350 
912 |a GBV_ILN_2005 
951 |a AR 
952 |d 16  |j 2009  |e Pt 5  |b 23  |c 09  |h 610-5