|
|
|
|
LEADER |
01000naa a22002652 4500 |
001 |
NLM189373539 |
003 |
DE-627 |
005 |
20231223183529.0 |
007 |
cr uuu---uuuuu |
008 |
231223s2009 xx |||||o 00| ||eng c |
024 |
7 |
|
|a 10.1107/S0909049509018986
|2 doi
|
028 |
5 |
2 |
|a pubmed24n0631.xml
|
035 |
|
|
|a (DE-627)NLM189373539
|
035 |
|
|
|a (NLM)19535864
|
040 |
|
|
|a DE-627
|b ger
|c DE-627
|e rakwb
|
041 |
|
|
|a eng
|
100 |
1 |
|
|a Knaapila, M
|e verfasserin
|4 aut
|
245 |
1 |
2 |
|a A new small-angle X-ray scattering set-up on the crystallography beamline I711 at MAX-lab
|
264 |
|
1 |
|c 2009
|
336 |
|
|
|a Text
|b txt
|2 rdacontent
|
337 |
|
|
|a ƒaComputermedien
|b c
|2 rdamedia
|
338 |
|
|
|a ƒa Online-Ressource
|b cr
|2 rdacarrier
|
500 |
|
|
|a Date Completed 05.11.2009
|
500 |
|
|
|a Date Revised 18.06.2009
|
500 |
|
|
|a published: Print-Electronic
|
500 |
|
|
|a Citation Status MEDLINE
|
520 |
|
|
|a A small-angle X-ray scattering (SAXS) set-up has recently been developed at beamline I711 at the MAX II storage ring in Lund (Sweden). An overview of the required modifications is presented here together with a number of application examples. The accessible q range in a SAXS experiment is 0.009-0.3 A(-1) for the standard set-up but depends on the sample-to-detector distance, detector offset, beamstop size and wavelength. The SAXS camera has been designed to have a low background and has three collinear slit sets for collimating the incident beam. The standard beam size is about 0.37 mm x 0.37 mm (full width at half-maximum) at the sample position, with a flux of 4 x 10(10) photons s(-1) and lambda = 1.1 A. The vacuum is of the order of 0.05 mbar in the unbroken beam path from the first slits until the exit window in front of the detector. A large sample chamber with a number of lead-throughs allows different sample environments to be mounted. This station is used for measurements on weakly scattering proteins in solutions and also for colloids, polymers and other nanoscale structures. A special application supported by the beamline is the effort to establish a micro-fluidic sample environment for structural analysis of samples that are only available in limited quantities. Overall, this work demonstrates how a cost-effective SAXS station can be constructed on a multipurpose beamline
|
650 |
|
4 |
|a Journal Article
|
650 |
|
4 |
|a Research Support, Non-U.S. Gov't
|
650 |
|
7 |
|a Lactalbumin
|2 NLM
|
650 |
|
7 |
|a 9013-90-5
|2 NLM
|
700 |
1 |
|
|a Svensson, C
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Barauskas, J
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Zackrisson, M
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Nielsen, S S
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Toft, K N
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Vestergaard, B
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Arleth, L
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Olsson, U
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Pedersen, J S
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Cerenius, Y
|e verfasserin
|4 aut
|
773 |
0 |
8 |
|i Enthalten in
|t Journal of synchrotron radiation
|d 1994
|g 16(2009), Pt 4 vom: 15. Juli, Seite 498-504
|w (DE-627)NLM09824129X
|x 1600-5775
|7 nnns
|
773 |
1 |
8 |
|g volume:16
|g year:2009
|g number:Pt 4
|g day:15
|g month:07
|g pages:498-504
|
856 |
4 |
0 |
|u http://dx.doi.org/10.1107/S0909049509018986
|3 Volltext
|
912 |
|
|
|a GBV_USEFLAG_A
|
912 |
|
|
|a SYSFLAG_A
|
912 |
|
|
|a GBV_NLM
|
912 |
|
|
|a GBV_ILN_40
|
912 |
|
|
|a GBV_ILN_350
|
912 |
|
|
|a GBV_ILN_2005
|
951 |
|
|
|a AR
|
952 |
|
|
|d 16
|j 2009
|e Pt 4
|b 15
|c 07
|h 498-504
|