|
|
|
|
LEADER |
01000naa a22002652 4500 |
001 |
NLM189116951 |
003 |
DE-627 |
005 |
20231223183103.0 |
007 |
cr uuu---uuuuu |
008 |
231223s2009 xx |||||o 00| ||eng c |
024 |
7 |
|
|a 10.1021/la900573w
|2 doi
|
028 |
5 |
2 |
|a pubmed24n0630.xml
|
035 |
|
|
|a (DE-627)NLM189116951
|
035 |
|
|
|a (NLM)19505126
|
040 |
|
|
|a DE-627
|b ger
|c DE-627
|e rakwb
|
041 |
|
|
|a eng
|
100 |
1 |
|
|a Carr, Joshua K
|e verfasserin
|4 aut
|
245 |
1 |
0 |
|a Heterogeneous translational dynamics of rhodamine B in polyelectrolyte multilayer thin films observed by single molecule microscopy
|
264 |
|
1 |
|c 2009
|
336 |
|
|
|a Text
|b txt
|2 rdacontent
|
337 |
|
|
|a ƒaComputermedien
|b c
|2 rdamedia
|
338 |
|
|
|a ƒa Online-Ressource
|b cr
|2 rdacarrier
|
500 |
|
|
|a Date Completed 17.09.2009
|
500 |
|
|
|a Date Revised 14.07.2009
|
500 |
|
|
|a published: Print
|
500 |
|
|
|a Citation Status PubMed-not-MEDLINE
|
520 |
|
|
|a The lateral diffusion dynamics of rhodamine B (RB) in polyelectrolyte multilayer (PEM) thin films has been studied with single-molecule confocal fluorescence microscopy. The films were made with sodium poly(sodium 4-styrenesulfonate) (PSS) and poly(diallydimethlyammonium chloride) (PDDA). Analysis of the real-time emission intensity traces reveals three diverse components of translational motion: (1) fast diffusion of RB through the confocal detection volume; (2) reversible tracer adsorption processes; and (3) nanoconfined diffusion. These processes cover a wide range of time scales. Analysis via fluorescence correlation spectroscopy (FCS) involves multicomponent fitting of the autocorrelated emission data. The model includes a free Brownian diffusion parameter, D, and two rate constants of desorption, k(-1) and k(-2). For RB in a PSS/PDDA thin film made with 0.01 M NaCl in the polyelectrolyte buildup solutions, D = 1.7 x 10(-7) cm(2)/s, k(-1) = 30 s(-1), and k(-2) = 0.1 s(-1). FCS was also performed on RB/PEM samples made with NaCl concentrations of the buildup solutions ranging from 0.01 to 0.7 M. A weak dependence of D and k(-1) on NaCl concentration was observed while k(-2) increased linearly with [NaCl]
|
650 |
|
4 |
|a Journal Article
|
700 |
1 |
|
|a Himes, Ryan D
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Keung, Connie H
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Burden, Daniel L
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Walhout, Peter K
|e verfasserin
|4 aut
|
773 |
0 |
8 |
|i Enthalten in
|t Langmuir : the ACS journal of surfaces and colloids
|d 1999
|g 25(2009), 14 vom: 21. Juli, Seite 8330-9
|w (DE-627)NLM098181009
|x 1520-5827
|7 nnns
|
773 |
1 |
8 |
|g volume:25
|g year:2009
|g number:14
|g day:21
|g month:07
|g pages:8330-9
|
856 |
4 |
0 |
|u http://dx.doi.org/10.1021/la900573w
|3 Volltext
|
912 |
|
|
|a GBV_USEFLAG_A
|
912 |
|
|
|a SYSFLAG_A
|
912 |
|
|
|a GBV_NLM
|
912 |
|
|
|a GBV_ILN_22
|
912 |
|
|
|a GBV_ILN_350
|
912 |
|
|
|a GBV_ILN_721
|
951 |
|
|
|a AR
|
952 |
|
|
|d 25
|j 2009
|e 14
|b 21
|c 07
|h 8330-9
|