New design for an endoesophageal sector- based array for the treatment of atrial fibrillation : a parametric simulation study

Atrial fibrillation (AF) is the most frequent and sustained cardiac arrhythmia affecting humans. The electrical isolation by ablation of the pulmonary veins (PV) in the left atrium (LA) of the heart has proved to be an effective cure for the AF. The ablation consists mainly of the formation of a loc...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on ultrasonics, ferroelectrics, and frequency control. - 1986. - 56(2009), 3 vom: 01. März, Seite 600-12
1. Verfasser: Pichardo, Samuel (VerfasserIn)
Weitere Verfasser: Hynynen, Kullervo
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2009
Zugriff auf das übergeordnete Werk:IEEE transactions on ultrasonics, ferroelectrics, and frequency control
Schlagworte:Journal Article Research Support, N.I.H., Extramural Research Support, Non-U.S. Gov't
LEADER 01000naa a22002652 4500
001 NLM188234748
003 DE-627
005 20231223181549.0
007 cr uuu---uuuuu
008 231223s2009 xx |||||o 00| ||eng c
024 7 |a 10.1109/TUFFC.2009.1076  |2 doi 
028 5 2 |a pubmed24n0628.xml 
035 |a (DE-627)NLM188234748 
035 |a (NLM)19411218 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Pichardo, Samuel  |e verfasserin  |4 aut 
245 1 0 |a New design for an endoesophageal sector- based array for the treatment of atrial fibrillation  |b a parametric simulation study 
264 1 |c 2009 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 27.08.2009 
500 |a Date Revised 04.05.2009 
500 |a published: Print 
500 |a Citation Status MEDLINE 
520 |a Atrial fibrillation (AF) is the most frequent and sustained cardiac arrhythmia affecting humans. The electrical isolation by ablation of the pulmonary veins (PV) in the left atrium (LA) of the heart has proved to be an effective cure for the AF. The ablation consists mainly of the formation of a localized circumferential thermal coagulation of the cardiac tissue surrounding the PVs. In this article, a parametric study was carried out to establish an optimal configuration of endesophageal ultrasound phased arrays intended to treat the AF. The devices are spherical-surface sections truncated at 15 mm, with a depth of 4 mm, and they are cut in concentric-rings, each composed of independently driven sectors. The number of independent elements (N(e)) was minimized for different values of ratio of pressure amplitude of the secondary lobe over the main lobe (eta) of 0.35, 0.4, 0.45, and 0.5 inside a volume of interest (VOI). After assuming a Cartesian system with the origin in the center of the device, the VOI was defined as the prism enclosed by the coordinates (-12, 10, -9) mm and (12, 37, 9) mm. The VOI has its center at (0, 23.5, 0) mm and is large enough to contain all the targets identified in the Visible Human Project Male specimen. Operating at 1 MHz, eta and N(e)were calculated in function of the element size and focal length (F). Four devices for each value of eta were found. After keeping values of F and normalized dimensions of the independent elements in terms of wavelength, higher frequencies were considered: 1.25 MHz, 1.5 MHz, and 2 MHz. In total, 16 device configurations were obtained. Realistic modeling of lesion formation in the heart chamber showed that the 16 configurations were able to produce the typical lesion used to treat the AF while preserving surrounding structures. At higher frequencies, lower power was required, and a greater number of array elements was required. For an exposure of 5 s and a maximum temperature of 70 degrees C, the average (+/-s.d.) acoustical intensity at transducer surface varied from 22.3(+/-5.8) W/cm(2) for a device with F = 98 mm at 1 MHz to 5.8(+/-1.2) W/cm(2) for a device with F = 186 mm at 2 MHz, while requiring 319 and 2093 elements, respectively, and achieving values of eta of 0.5 and 0.41, respectively. For the intended application, the selected devices implied a better focusing when compared with more traditional planar 2-D arrays, while requiring less power and fewer independent elements 
650 4 |a Journal Article 
650 4 |a Research Support, N.I.H., Extramural 
650 4 |a Research Support, Non-U.S. Gov't 
700 1 |a Hynynen, Kullervo  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t IEEE transactions on ultrasonics, ferroelectrics, and frequency control  |d 1986  |g 56(2009), 3 vom: 01. März, Seite 600-12  |w (DE-627)NLM098181017  |x 1525-8955  |7 nnns 
773 1 8 |g volume:56  |g year:2009  |g number:3  |g day:01  |g month:03  |g pages:600-12 
856 4 0 |u http://dx.doi.org/10.1109/TUFFC.2009.1076  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_22 
912 |a GBV_ILN_24 
912 |a GBV_ILN_350 
951 |a AR 
952 |d 56  |j 2009  |e 3  |b 01  |c 03  |h 600-12