Picosecond time-resolved laser pump/X-ray probe experiments using a gated single-photon-counting area detector

The recent developments in X-ray detectors have opened new possibilities in the area of time-resolved pump/probe X-ray experiments; this article presents the novel use of a PILATUS detector to achieve X-ray pulse duration limited time-resolution at the Advanced Photon Source (APS), USA. The capabili...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Journal of synchrotron radiation. - 1994. - 16(2009), Pt 3 vom: 25. Mai, Seite 387-90
1. Verfasser: Ejdrup, T (VerfasserIn)
Weitere Verfasser: Lemke, H T, Haldrup, K, Nielsen, T N, Arms, D A, Walko, D A, Miceli, A, Landahl, E C, Dufresne, E M, Nielsen, M M
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2009
Zugriff auf das übergeordnete Werk:Journal of synchrotron radiation
Schlagworte:Journal Article Research Support, Non-U.S. Gov't Research Support, U.S. Gov't, Non-P.H.S.
LEADER 01000caa a22002652 4500
001 NLM188092668
003 DE-627
005 20250210090558.0
007 cr uuu---uuuuu
008 231223s2009 xx |||||o 00| ||eng c
024 7 |a 10.1107/S0909049509004658  |2 doi 
028 5 2 |a pubmed25n0627.xml 
035 |a (DE-627)NLM188092668 
035 |a (NLM)19395803 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Ejdrup, T  |e verfasserin  |4 aut 
245 1 0 |a Picosecond time-resolved laser pump/X-ray probe experiments using a gated single-photon-counting area detector 
264 1 |c 2009 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 09.07.2009 
500 |a Date Revised 27.04.2009 
500 |a published: Print-Electronic 
500 |a Citation Status MEDLINE 
520 |a The recent developments in X-ray detectors have opened new possibilities in the area of time-resolved pump/probe X-ray experiments; this article presents the novel use of a PILATUS detector to achieve X-ray pulse duration limited time-resolution at the Advanced Photon Source (APS), USA. The capability of the gated PILATUS detector to selectively detect the signal from a given X-ray pulse in 24 bunch mode at the APS storage ring is demonstrated. A test experiment performed on polycrystalline organic thin films of alpha-perylene illustrates the possibility of reaching an X-ray pulse duration limited time-resolution of 60 ps using the gated PILATUS detector. This is the first demonstration of X-ray pulse duration limited data recorded using an area detector without the use of a mechanical chopper array at the beamline 
650 4 |a Journal Article 
650 4 |a Research Support, Non-U.S. Gov't 
650 4 |a Research Support, U.S. Gov't, Non-P.H.S. 
700 1 |a Lemke, H T  |e verfasserin  |4 aut 
700 1 |a Haldrup, K  |e verfasserin  |4 aut 
700 1 |a Nielsen, T N  |e verfasserin  |4 aut 
700 1 |a Arms, D A  |e verfasserin  |4 aut 
700 1 |a Walko, D A  |e verfasserin  |4 aut 
700 1 |a Miceli, A  |e verfasserin  |4 aut 
700 1 |a Landahl, E C  |e verfasserin  |4 aut 
700 1 |a Dufresne, E M  |e verfasserin  |4 aut 
700 1 |a Nielsen, M M  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Journal of synchrotron radiation  |d 1994  |g 16(2009), Pt 3 vom: 25. Mai, Seite 387-90  |w (DE-627)NLM09824129X  |x 1600-5775  |7 nnns 
773 1 8 |g volume:16  |g year:2009  |g number:Pt 3  |g day:25  |g month:05  |g pages:387-90 
856 4 0 |u http://dx.doi.org/10.1107/S0909049509004658  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_40 
912 |a GBV_ILN_350 
912 |a GBV_ILN_2005 
951 |a AR 
952 |d 16  |j 2009  |e Pt 3  |b 25  |c 05  |h 387-90