T2 relaxation measurement with solvent suppression and implications to solvent suppression in general

2009 John Wiley & Sons, Ltd.

Bibliographische Detailangaben
Veröffentlicht in:Magnetic resonance in chemistry : MRC. - 1985. - 47(2009), 7 vom: 30. Juli, Seite 593-600
1. Verfasser: Hoffmann, Markus M (VerfasserIn)
Weitere Verfasser: Sobstyl, Hanna S, Badali, Vincent A
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2009
Zugriff auf das übergeordnete Werk:Magnetic resonance in chemistry : MRC
Schlagworte:Journal Article
LEADER 01000naa a22002652 4500
001 NLM18788529X
003 DE-627
005 20231223180929.0
007 cr uuu---uuuuu
008 231223s2009 xx |||||o 00| ||eng c
024 7 |a 10.1002/mrc.2434  |2 doi 
028 5 2 |a pubmed24n0626.xml 
035 |a (DE-627)NLM18788529X 
035 |a (NLM)19373850 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Hoffmann, Markus M  |e verfasserin  |4 aut 
245 1 0 |a T2 relaxation measurement with solvent suppression and implications to solvent suppression in general 
264 1 |c 2009 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 12.08.2009 
500 |a Date Revised 09.06.2009 
500 |a published: Print 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a 2009 John Wiley & Sons, Ltd. 
520 |a A number of suppression pulse sequences including Excitation Sculpting and WATERGATE were incorporated into the standard Carr-Purcell-Meiboom-Gill (CPMG) program for T(2) measurement and experimentally evaluated. The chosen suppression schemes were of varying complexity encompassing pulse program elements, such as presaturation, gradients, and selective pulses, which are typically utilized for solvent suppression. The quality of the spectral data and the accuracy of T(2) measurements of the investigated suppression schemes were evaluated using three aqueous samples with increasing proton content in the water solvent, i.e. by volume 100% D(2)O, 80/20% D(2)O/H(2)O, and 20/80% D(2)O/H(2)O. For signals removed from the water signal, the T(2) values were generally very consistent between all pulse sequences tested. T(2) measurements can be unreliable for signals too close to the water signal such that they are significantly suppressed as well. Their intensity may actually grow initially through cross relaxation that transfers magnetization back to the solute signal. In turn, this relaxation phenomenon can be exploited to improve the spectral quality of conventional solvent suppression schemes. In favorable cases, even signals that are completely masked by the water signal can be recovered by adding a carefully chosen number of spin echoes with optimized evolution time to conventional water suppression pulse programs, such as Excitation Sculpting or WATERGATE 
650 4 |a Journal Article 
700 1 |a Sobstyl, Hanna S  |e verfasserin  |4 aut 
700 1 |a Badali, Vincent A  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Magnetic resonance in chemistry : MRC  |d 1985  |g 47(2009), 7 vom: 30. Juli, Seite 593-600  |w (DE-627)NLM098179667  |x 1097-458X  |7 nnns 
773 1 8 |g volume:47  |g year:2009  |g number:7  |g day:30  |g month:07  |g pages:593-600 
856 4 0 |u http://dx.doi.org/10.1002/mrc.2434  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_350 
951 |a AR 
952 |d 47  |j 2009  |e 7  |b 30  |c 07  |h 593-600