The RATIO method for time-resolved Laue crystallography

A RATIO method for analysis of intensity changes in time-resolved pump-probe Laue diffraction experiments is described. The method eliminates the need for scaling the data with a wavelength curve representing the spectral distribution of the source and removes the effect of possible anisotropic abso...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Journal of synchrotron radiation. - 1994. - 16(2009), Pt 2 vom: 13. März, Seite 226-30
1. Verfasser: Coppens, Philip (VerfasserIn)
Weitere Verfasser: Pitak, Mateusz, Gembicky, Milan, Messerschmidt, Marc, Scheins, Stephan, Benedict, Jason, Adachi, Shin Ichi, Sato, Tokushi, Nozawa, Shunsuke, Ichiyanagi, Kohei, Chollet, Matthieu, Koshihara, Shin Ya
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2009
Zugriff auf das übergeordnete Werk:Journal of synchrotron radiation
Schlagworte:Evaluation Study Journal Article Research Support, N.I.H., Extramural Research Support, U.S. Gov't, Non-P.H.S.
LEADER 01000caa a22002652 4500
001 NLM186653190
003 DE-627
005 20250210052621.0
007 cr uuu---uuuuu
008 231223s2009 xx |||||o 00| ||eng c
024 7 |a 10.1107/S0909049508040892  |2 doi 
028 5 2 |a pubmed25n0622.xml 
035 |a (DE-627)NLM186653190 
035 |a (NLM)19240334 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Coppens, Philip  |e verfasserin  |4 aut 
245 1 4 |a The RATIO method for time-resolved Laue crystallography 
264 1 |c 2009 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 28.04.2009 
500 |a Date Revised 20.10.2021 
500 |a published: Print-Electronic 
500 |a Citation Status MEDLINE 
520 |a A RATIO method for analysis of intensity changes in time-resolved pump-probe Laue diffraction experiments is described. The method eliminates the need for scaling the data with a wavelength curve representing the spectral distribution of the source and removes the effect of possible anisotropic absorption. It does not require relative scaling of series of frames and removes errors due to all but very short term fluctuations in the synchrotron beam 
650 4 |a Evaluation Study 
650 4 |a Journal Article 
650 4 |a Research Support, N.I.H., Extramural 
650 4 |a Research Support, U.S. Gov't, Non-P.H.S. 
700 1 |a Pitak, Mateusz  |e verfasserin  |4 aut 
700 1 |a Gembicky, Milan  |e verfasserin  |4 aut 
700 1 |a Messerschmidt, Marc  |e verfasserin  |4 aut 
700 1 |a Scheins, Stephan  |e verfasserin  |4 aut 
700 1 |a Benedict, Jason  |e verfasserin  |4 aut 
700 1 |a Adachi, Shin Ichi  |e verfasserin  |4 aut 
700 1 |a Sato, Tokushi  |e verfasserin  |4 aut 
700 1 |a Nozawa, Shunsuke  |e verfasserin  |4 aut 
700 1 |a Ichiyanagi, Kohei  |e verfasserin  |4 aut 
700 1 |a Chollet, Matthieu  |e verfasserin  |4 aut 
700 1 |a Koshihara, Shin Ya  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Journal of synchrotron radiation  |d 1994  |g 16(2009), Pt 2 vom: 13. März, Seite 226-30  |w (DE-627)NLM09824129X  |x 1600-5775  |7 nnns 
773 1 8 |g volume:16  |g year:2009  |g number:Pt 2  |g day:13  |g month:03  |g pages:226-30 
856 4 0 |u http://dx.doi.org/10.1107/S0909049508040892  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_40 
912 |a GBV_ILN_350 
912 |a GBV_ILN_2005 
951 |a AR 
952 |d 16  |j 2009  |e Pt 2  |b 13  |c 03  |h 226-30