Quasi-equilibrium AFM measurement of disjoining pressure in lubricant nanofilms II : Effect of substrate materials

Atomic force microscopy (AFM) was used to measure the disjoining pressures of perfluoropolyether lubricant films (0.8-4.3 nm of Fomblin Z03) on both silicon wafers and hard drive disks coated with a diamondlike carbon overcoat. Differences in the disjoining pressure between the two systems were expe...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Langmuir : the ACS journal of surfaces and colloids. - 1992. - 25(2009), 4 vom: 17. Feb., Seite 2101-6
1. Verfasser: Bowles, Adam P (VerfasserIn)
Weitere Verfasser: Hsia, Yiao-Tee, Jones, Paul M, White, Lee R, Schneider, James W
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2009
Zugriff auf das übergeordnete Werk:Langmuir : the ACS journal of surfaces and colloids
Schlagworte:Journal Article
LEADER 01000naa a22002652 4500
001 NLM185998216
003 DE-627
005 20231223173452.0
007 cr uuu---uuuuu
008 231223s2009 xx |||||o 00| ||eng c
024 7 |a 10.1021/la8024638  |2 doi 
028 5 2 |a pubmed24n0620.xml 
035 |a (DE-627)NLM185998216 
035 |a (NLM)19170526 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Bowles, Adam P  |e verfasserin  |4 aut 
245 1 0 |a Quasi-equilibrium AFM measurement of disjoining pressure in lubricant nanofilms II  |b Effect of substrate materials 
264 1 |c 2009 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 31.03.2009 
500 |a Date Revised 09.03.2009 
500 |a published: Print 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a Atomic force microscopy (AFM) was used to measure the disjoining pressures of perfluoropolyether lubricant films (0.8-4.3 nm of Fomblin Z03) on both silicon wafers and hard drive disks coated with a diamondlike carbon overcoat. Differences in the disjoining pressure between the two systems were expected to be due to variations in the strength of van der Waals interactions. Lifshitz theory calculations suggest that this substrate switch will lead to relatively small changes in disjoining pressure as compared to the more pronounced effects reported due to changes in lubricant chemistry. We demonstrate the sensitivity of our AFM method by distinguishing between these similar systems 
650 4 |a Journal Article 
700 1 |a Hsia, Yiao-Tee  |e verfasserin  |4 aut 
700 1 |a Jones, Paul M  |e verfasserin  |4 aut 
700 1 |a White, Lee R  |e verfasserin  |4 aut 
700 1 |a Schneider, James W  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Langmuir : the ACS journal of surfaces and colloids  |d 1992  |g 25(2009), 4 vom: 17. Feb., Seite 2101-6  |w (DE-627)NLM098181009  |x 1520-5827  |7 nnns 
773 1 8 |g volume:25  |g year:2009  |g number:4  |g day:17  |g month:02  |g pages:2101-6 
856 4 0 |u http://dx.doi.org/10.1021/la8024638  |3 Volltext 