Capturing molecular structural dynamics by 100 ps time-resolved X-ray absorption spectroscopy

An experimental set-up for time-resolved X-ray absorption spectroscopy with 100 ps time resolution at beamline NW14A at the Photon Factory Advanced Ring is presented. The X-ray positional active feedback to crystals in a monochromator combined with a figure-of-merit scan of the laser beam position h...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Journal of synchrotron radiation. - 1994. - 16(2009), Pt 1 vom: 13. Jan., Seite 110-5
1. Verfasser: Sato, Tokushi (VerfasserIn)
Weitere Verfasser: Nozawa, Shunsuke, Ichiyanagi, Kohei, Tomita, Ayana, Chollet, Matthieu, Ichikawa, Hirohiko, Fujii, Hiroshi, Adachi, Shin Ichi, Koshihara, Shin Ya
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2009
Zugriff auf das übergeordnete Werk:Journal of synchrotron radiation
Schlagworte:Journal Article Research Support, Non-U.S. Gov't
LEADER 01000caa a22002652 4500
001 NLM185302505
003 DE-627
005 20250210011354.0
007 cr uuu---uuuuu
008 231223s2009 xx |||||o 00| ||eng c
024 7 |a 10.1107/S0909049508034596  |2 doi 
028 5 2 |a pubmed25n0618.xml 
035 |a (DE-627)NLM185302505 
035 |a (NLM)19096182 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Sato, Tokushi  |e verfasserin  |4 aut 
245 1 0 |a Capturing molecular structural dynamics by 100 ps time-resolved X-ray absorption spectroscopy 
264 1 |c 2009 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 25.02.2009 
500 |a Date Revised 20.10.2021 
500 |a published: Print-Electronic 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a An experimental set-up for time-resolved X-ray absorption spectroscopy with 100 ps time resolution at beamline NW14A at the Photon Factory Advanced Ring is presented. The X-ray positional active feedback to crystals in a monochromator combined with a figure-of-merit scan of the laser beam position has been utilized as an essential tool to stabilize the spatial overlap of the X-ray and laser beams at the sample position. As a typical example, a time-resolved XAFS measurement of a photo-induced spin crossover reaction of the tris(1,10-phenanthrorine)iron(II) complex in water is presented 
650 4 |a Journal Article 
650 4 |a Research Support, Non-U.S. Gov't 
700 1 |a Nozawa, Shunsuke  |e verfasserin  |4 aut 
700 1 |a Ichiyanagi, Kohei  |e verfasserin  |4 aut 
700 1 |a Tomita, Ayana  |e verfasserin  |4 aut 
700 1 |a Chollet, Matthieu  |e verfasserin  |4 aut 
700 1 |a Ichikawa, Hirohiko  |e verfasserin  |4 aut 
700 1 |a Fujii, Hiroshi  |e verfasserin  |4 aut 
700 1 |a Adachi, Shin Ichi  |e verfasserin  |4 aut 
700 1 |a Koshihara, Shin Ya  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Journal of synchrotron radiation  |d 1994  |g 16(2009), Pt 1 vom: 13. Jan., Seite 110-5  |w (DE-627)NLM09824129X  |x 1600-5775  |7 nnns 
773 1 8 |g volume:16  |g year:2009  |g number:Pt 1  |g day:13  |g month:01  |g pages:110-5 
856 4 0 |u http://dx.doi.org/10.1107/S0909049508034596  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_40 
912 |a GBV_ILN_350 
912 |a GBV_ILN_2005 
951 |a AR 
952 |d 16  |j 2009  |e Pt 1  |b 13  |c 01  |h 110-5