High frame-rate blood vector velocity imaging using plane waves : simulations and preliminary experiments

Conventional ultrasound methods for acquiring color images of blood velocity are limited by a relatively low frame-rate and are restricted to give velocity estimates along the ultrasound beam direction only. To circumvent these limitations, the method presented in this paper uses 3 techniques: 1) Th...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on ultrasonics, ferroelectrics, and frequency control. - 1986. - 55(2008), 8 vom: 15. Aug., Seite 1729-43
1. Verfasser: Udesen, Jesper (VerfasserIn)
Weitere Verfasser: Gran, Fredrik, Hansen, Kristoffer Lindskov, Jensen, Jørgen Arendt, Thomsen, Carsten, Nielsen, Michael Bachmann
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2008
Zugriff auf das übergeordnete Werk:IEEE transactions on ultrasonics, ferroelectrics, and frequency control
Schlagworte:Evaluation Study Journal Article
LEADER 01000naa a22002652 4500
001 NLM184308410
003 DE-627
005 20231223170354.0
007 cr uuu---uuuuu
008 231223s2008 xx |||||o 00| ||eng c
024 7 |a 10.1109/TUFFC.2008.858  |2 doi 
028 5 2 |a pubmed24n0614.xml 
035 |a (DE-627)NLM184308410 
035 |a (NLM)18986917 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Udesen, Jesper  |e verfasserin  |4 aut 
245 1 0 |a High frame-rate blood vector velocity imaging using plane waves  |b simulations and preliminary experiments 
264 1 |c 2008 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 30.01.2009 
500 |a Date Revised 10.03.2022 
500 |a published: Print 
500 |a Citation Status MEDLINE 
520 |a Conventional ultrasound methods for acquiring color images of blood velocity are limited by a relatively low frame-rate and are restricted to give velocity estimates along the ultrasound beam direction only. To circumvent these limitations, the method presented in this paper uses 3 techniques: 1) The ultrasound is not focused during the transmissions of the ultrasound signals; 2) A 13-bit Barker code is transmitted simultaneously from each transducer element; and 3) The 2-D vector velocity of the blood is estimated using 2-D cross-correlation. A parameter study was performed using the Field II program, and performance of the method was investigated when a virtual blood vessel was scanned by a linear array transducer. An improved parameter set for the method was identified from the parameter study, and a flow rig measurement was performed using the same improved setup as in the simulations. Finally, the common carotid artery of a healthy male was scanned with a scan sequence that satisfies the limits set by the Food and Drug Administration. Vector velocity images were obtained with a frame-rate of 100 Hz where 40 speckle images are used for each vector velocity image. It was found that the blood flow approximately followed the vessel wall, and that maximum velocity was approximately 1 m/s, which is a normal value for a healthy person. To further evaluate the method, the test person was scanned with magnetic resonance (MR) angiography. The volume flow derived from the MR scanning was compared with that from the ultrasound scanning. A deviation of 9% between the 2 volume flow estimates was found 
650 4 |a Evaluation Study 
650 4 |a Journal Article 
700 1 |a Gran, Fredrik  |e verfasserin  |4 aut 
700 1 |a Hansen, Kristoffer Lindskov  |e verfasserin  |4 aut 
700 1 |a Jensen, Jørgen Arendt  |e verfasserin  |4 aut 
700 1 |a Thomsen, Carsten  |e verfasserin  |4 aut 
700 1 |a Nielsen, Michael Bachmann  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t IEEE transactions on ultrasonics, ferroelectrics, and frequency control  |d 1986  |g 55(2008), 8 vom: 15. Aug., Seite 1729-43  |w (DE-627)NLM098181017  |x 1525-8955  |7 nnns 
773 1 8 |g volume:55  |g year:2008  |g number:8  |g day:15  |g month:08  |g pages:1729-43 
856 4 0 |u http://dx.doi.org/10.1109/TUFFC.2008.858  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_22 
912 |a GBV_ILN_24 
912 |a GBV_ILN_350 
951 |a AR 
952 |d 55  |j 2008  |e 8  |b 15  |c 08  |h 1729-43