High-numerical-aperture-based virtual point detectors for photoacoustic tomography

The focal point of a high-numerical-aperture (NA) ultrasonic transducer can be used as a virtual point detector. This virtual point detector detects omnidirectionally over a wide acceptance angle. It also combines a large active transducer surface and a small effective virtual detector size. Thus th...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Applied physics letters. - 1998. - 93(2008), 3 vom: 21. Juli, Seite 33902
1. Verfasser: Li, Changhui (VerfasserIn)
Weitere Verfasser: Wang, Lihong V
Format: Aufsatz
Sprache:English
Veröffentlicht: 2008
Zugriff auf das übergeordnete Werk:Applied physics letters
Schlagworte:Journal Article
LEADER 01000caa a22002652 4500
001 NLM182527549
003 DE-627
005 20250209183240.0
007 tu
008 231223s2008 xx ||||| 00| ||eng c
028 5 2 |a pubmed25n0609.xml 
035 |a (DE-627)NLM182527549 
035 |a (NLM)18802493 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Li, Changhui  |e verfasserin  |4 aut 
245 1 0 |a High-numerical-aperture-based virtual point detectors for photoacoustic tomography 
264 1 |c 2008 
336 |a Text  |b txt  |2 rdacontent 
337 |a ohne Hilfsmittel zu benutzen  |b n  |2 rdamedia 
338 |a Band  |b nc  |2 rdacarrier 
500 |a Date Revised 29.09.2020 
500 |a published: Print-Electronic 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a The focal point of a high-numerical-aperture (NA) ultrasonic transducer can be used as a virtual point detector. This virtual point detector detects omnidirectionally over a wide acceptance angle. It also combines a large active transducer surface and a small effective virtual detector size. Thus the sensitivity is high compared with that of a real point detector, and the aperture effect is small compared with that of a finite size transducer. We present two kinds of high-NA-based virtual point detectors and their successful application in photoacoustic tomography. They can also be applied in other ultrasound-related fields 
650 4 |a Journal Article 
700 1 |a Wang, Lihong V  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Applied physics letters  |d 1998  |g 93(2008), 3 vom: 21. Juli, Seite 33902  |w (DE-627)NLM098165984  |x 0003-6951  |7 nnns 
773 1 8 |g volume:93  |g year:2008  |g number:3  |g day:21  |g month:07  |g pages:33902 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_21 
912 |a GBV_ILN_24 
912 |a GBV_ILN_350 
951 |a AR 
952 |d 93  |j 2008  |e 3  |b 21  |c 07  |h 33902