|
|
|
|
LEADER |
01000caa a22002652c 4500 |
001 |
NLM181157527 |
003 |
DE-627 |
005 |
20250209153338.0 |
007 |
cr uuu---uuuuu |
008 |
231223s2008 xx |||||o 00| ||eng c |
024 |
7 |
|
|a 10.2166/wst.2008.644
|2 doi
|
028 |
5 |
2 |
|a pubmed25n0604.xml
|
035 |
|
|
|a (DE-627)NLM181157527
|
035 |
|
|
|a (NLM)18653948
|
040 |
|
|
|a DE-627
|b ger
|c DE-627
|e rakwb
|
041 |
|
|
|a eng
|
100 |
1 |
|
|a Hu, Ruikang
|e verfasserin
|4 aut
|
245 |
1 |
0 |
|a Picogram determination of N-nitrosodimethylamine in water
|
264 |
|
1 |
|c 2008
|
336 |
|
|
|a Text
|b txt
|2 rdacontent
|
337 |
|
|
|a ƒaComputermedien
|b c
|2 rdamedia
|
338 |
|
|
|a ƒa Online-Ressource
|b cr
|2 rdacarrier
|
500 |
|
|
|a Date Completed 31.12.2008
|
500 |
|
|
|a Date Revised 21.11.2013
|
500 |
|
|
|a published: Print
|
500 |
|
|
|a Citation Status MEDLINE
|
520 |
|
|
|a (c) IWA Publishing 2008.
|
520 |
|
|
|a N-nitrosodimethylamine (NDMA) persistence within surface waters is a major concern for downstream communities exploiting these waters as drinking water supplies. The objective of this study is to develop a novel and efficient analytical method for NDMA via different technologies: pulsed splitless gas chromatography-nitrogen phosphorus detector (GC-NPD), large volume injection (LVI) gas chromatography-mass spectrometry (GC/MS) via programmable temperature vaporizer (PTV) inlet or PTV-gas chromatography-triple quadruple mass spectrometry (GC-MS/MS) and continuous liquid-liquid extraction. It was found that the sensitivity required for NDMA analysis by GC-NPD can only be achieved when the NPD bead is extremely clean. LVI via PTV can greatly improve GC-MS system sensitivity for analyzing NDMA. With the help of DB-624 (25 m x 200 microm x 1.12 microm) connected with DB-5MS (30 m x 250 microm x 0.25 microm) in series, PTV-GC/MS could overcome the matrix interference for the trace analysis of NDMA. Variable instrument conditions were studied in detail, with the optimized process being validated via precision and accuracy studies. PTV- triple quadruple GC-MS/MS system could efficiently remove the interference on a single DB-5MS (30 m x 250 microm x 0.25 microm) column with good sensitivity and selectivity. The developed methods have been successfully applied to test NDMA in different types of water samples with satisfactory results
|
650 |
|
4 |
|a Journal Article
|
650 |
|
7 |
|a Water
|2 NLM
|
650 |
|
7 |
|a 059QF0KO0R
|2 NLM
|
650 |
|
7 |
|a Dimethylnitrosamine
|2 NLM
|
650 |
|
7 |
|a M43H21IO8R
|2 NLM
|
700 |
1 |
|
|a Zhang, Lifeng
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Yang, Zhaoguang
|e verfasserin
|4 aut
|
773 |
0 |
8 |
|i Enthalten in
|t Water science and technology : a journal of the International Association on Water Pollution Research
|d 1986
|g 58(2008), 1 vom: 21., Seite 143-51
|w (DE-627)NLM098149431
|x 0273-1223
|7 nnas
|
773 |
1 |
8 |
|g volume:58
|g year:2008
|g number:1
|g day:21
|g pages:143-51
|
856 |
4 |
0 |
|u http://dx.doi.org/10.2166/wst.2008.644
|3 Volltext
|
912 |
|
|
|a GBV_USEFLAG_A
|
912 |
|
|
|a SYSFLAG_A
|
912 |
|
|
|a GBV_NLM
|
912 |
|
|
|a GBV_ILN_350
|
951 |
|
|
|a AR
|
952 |
|
|
|d 58
|j 2008
|e 1
|b 21
|h 143-51
|