LEADER |
01000caa a22002652c 4500 |
001 |
NLM180642510 |
003 |
DE-627 |
005 |
20250209143327.0 |
007 |
cr uuu---uuuuu |
008 |
231223s2008 xx |||||o 00| ||eng c |
024 |
7 |
|
|a 10.1109/TUFFC.2008.783
|2 doi
|
028 |
5 |
2 |
|a pubmed25n0602.xml
|
035 |
|
|
|a (DE-627)NLM180642510
|
035 |
|
|
|a (NLM)18599408
|
040 |
|
|
|a DE-627
|b ger
|c DE-627
|e rakwb
|
041 |
|
|
|a eng
|
100 |
1 |
|
|a Barkmann, Reinhard
|e verfasserin
|4 aut
|
245 |
1 |
2 |
|a A device for in vivo measurements of quantitative ultrasound variables at the human proximal femur
|
264 |
|
1 |
|c 2008
|
336 |
|
|
|a Text
|b txt
|2 rdacontent
|
337 |
|
|
|a ƒaComputermedien
|b c
|2 rdamedia
|
338 |
|
|
|a ƒa Online-Ressource
|b cr
|2 rdacarrier
|
500 |
|
|
|a Date Completed 02.09.2008
|
500 |
|
|
|a Date Revised 10.12.2019
|
500 |
|
|
|a published: Print
|
500 |
|
|
|a Citation Status MEDLINE
|
520 |
|
|
|a Quantitative ultrasound (QUS) at the calcaneus has similar power as a bone mineral density (BMD)- measurement using DXA for the prediction of osteoporotic fracture risk. Ultrasound equipment is less expensive than DXA and free of ionizing radiation. As a mechanical wave, QUS has the potential of measuring different bone properties than dual X-ray absorptiometry (DXA,) which depends on X-ray attenuation and might be developed into a tool of comprehensive assessment of bone strength. However, site-specific DXA at the proximal femur shows best performance in the prediction of hip fractures. To combine the potential of QUS with measurements directly at the femur, we developed a device for in vivo QUS measurements at this site. Methods comprise ultrasound transmission through the bone, reflection from the bone surface, and backscatter from the inner trabecular structure. The complete area of the proximal femur can be scanned except at the femoral head, which interferes with the ilium. To avoid edge artifacts, a subregion of the proximal femur in the trochanteric region was selected as measurement region. First, in vivo measurements demonstrate a good signal to noise ratio and proper depiction of the proximal femur on an attenuation image. Our results demonstrate the feasibility of in vivo measurements. Further improvements can be expected by refinement of the scanning technique and data evaluation method to enhance the potential of the new method for the estimation of bone strength
|
650 |
|
4 |
|a Evaluation Study
|
650 |
|
4 |
|a Journal Article
|
650 |
|
4 |
|a Research Support, Non-U.S. Gov't
|
700 |
1 |
|
|a Laugier, Pascal
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Moser, Urs
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Dencks, Stefanie
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Klausner, Michael
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Padilla, Frédéric
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Haïat, Guilleaume
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Glüer, Claus-C
|e verfasserin
|4 aut
|
773 |
0 |
8 |
|i Enthalten in
|t IEEE transactions on ultrasonics, ferroelectrics, and frequency control
|d 1986
|g 55(2008), 6 vom: 10., Seite 1197-204
|w (DE-627)NLM098181017
|x 1525-8955
|7 nnas
|
773 |
1 |
8 |
|g volume:55
|g year:2008
|g number:6
|g day:10
|g pages:1197-204
|
856 |
4 |
0 |
|u http://dx.doi.org/10.1109/TUFFC.2008.783
|3 Volltext
|
912 |
|
|
|a GBV_USEFLAG_A
|
912 |
|
|
|a SYSFLAG_A
|
912 |
|
|
|a GBV_NLM
|
912 |
|
|
|a GBV_ILN_22
|
912 |
|
|
|a GBV_ILN_24
|
912 |
|
|
|a GBV_ILN_350
|
951 |
|
|
|a AR
|
952 |
|
|
|d 55
|j 2008
|e 6
|b 10
|h 1197-204
|