On-line estimation of the dissolved zinc concentration during ZnS precipitation in a continuous stirred tank reactor (CSTR)

IWA Publishing 2008.

Détails bibliographiques
Publié dans:Water science and technology : a journal of the International Association on Water Pollution Research. - 1986. - 57(2008), 10 vom: 10., Seite 1627-33
Auteur principal: Grootscholten, T I M (Auteur)
Autres auteurs: Keesman, K J, Lens, P N L
Format: Article en ligne
Langue:English
Publié: 2008
Accès à la collection:Water science and technology : a journal of the International Association on Water Pollution Research
Sujets:Journal Article Sulfides Zinc Compounds Zinc J41CSQ7QDS zinc sulfide KPS085631O
Description
Résumé:IWA Publishing 2008.
In this paper a method is presented to estimate the reaction term of zinc sulphide precipitation and the zinc concentration in a CSTR, using the read-out signal of a sulphide selective electrode. The reaction between zinc and sulphide is described by a non-linear model and therefore classical observer theory cannot be applied directly, as this theory was initially developed for linear systems. However, by linear reparametrization of this non-linear system, the linear observer theory can be applied in an effective way. This is illustrated by a zinc sulphide example using real data
Description:Date Completed 18.11.2008
Date Revised 21.11.2013
published: Print
Citation Status MEDLINE
ISSN:0273-1223