Assessment of the reliability of an on-site MBR system for greywater treatment and the associated aesthetic and health risks
Copyright IWA Publishing 2008.
Veröffentlicht in: | Water science and technology : a journal of the International Association on Water Pollution Research. - 1986. - 57(2008), 7 vom: 21., Seite 1103-10 |
---|---|
1. Verfasser: | |
Weitere Verfasser: | , |
Format: | Online-Aufsatz |
Sprache: | English |
Veröffentlicht: |
2008
|
Zugriff auf das übergeordnete Werk: | Water science and technology : a journal of the International Association on Water Pollution Research |
Schlagworte: | Journal Article Research Support, Non-U.S. Gov't Water 059QF0KO0R |
Zusammenfassung: | Copyright IWA Publishing 2008. This study analyses the reliability of an on-site MBR system for greywater treatment and reuse. To achieve this goal simulation was performed based on the IWA ASM1 model which was adapted to describe biological and physical mechanisms for MBR greywater treatment based systems. Model results were found to agree well with experimental data from an on site pilot greywater treatment plant, after which the calibrated model was used in a Monte Carlo mode for generating statistical data on the MBR system performance under different scenarios of failures and inflow loads variations. Effluents quality and their associated risks were successfully estimated |
---|---|
Beschreibung: | Date Completed 05.09.2008 Date Revised 21.11.2013 published: Print Citation Status MEDLINE |
ISSN: | 0273-1223 |
DOI: | 10.2166/wst.2008.248 |