X-ray beam stabilization at BL-17A, the protein microcrystallography beamline of the Photon Factory

BL-17A is a new structural biology beamline at the Photon Factory, Japan. The high-brilliance beam, derived from the new short-gap undulator (SGU#17), allows for unique protein crystallographic experiments such as data collection from microcrystals and structural determination using softer X-rays. H...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Journal of synchrotron radiation. - 1994. - 15(2008), Pt 3 vom: 07. Mai, Seite 292-5
1. Verfasser: Igarashi, Noriyuki (VerfasserIn)
Weitere Verfasser: Ikuta, Kazuyuki, Miyoshi, Toshinobu, Matsugaki, Naohiro, Yamada, Yusuke, Yousef, Mohammad S, Wakatsuki, Soichi
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2008
Zugriff auf das übergeordnete Werk:Journal of synchrotron radiation
Schlagworte:Journal Article Research Support, Non-U.S. Gov't Proteins
Beschreibung
Zusammenfassung:BL-17A is a new structural biology beamline at the Photon Factory, Japan. The high-brilliance beam, derived from the new short-gap undulator (SGU#17), allows for unique protein crystallographic experiments such as data collection from microcrystals and structural determination using softer X-rays. However, microcrystal experiments require robust beam stability during data collection and minor fluctuations could not be ignored. Initially, significant beam instability was observed at BL-17A. The causes of the beam instability were investigated and its various sources identified. Subsequently, several effective countermeasures have been implemented, and the fluctuation of the beam intensity successfully suppressed to within 1%. Here the instability reduction techniques used at BL-17A are presented
Beschreibung:Date Completed 31.07.2008
Date Revised 20.10.2021
published: Print-Electronic
Citation Status MEDLINE
ISSN:1600-5775
DOI:10.1107/S0909049507067118