A digital hardware correlation system for fast ultrasonic data acquisition in peak power limited applications
The theoretical and experimental evaluation of a digital hardware correlation system for low-power ultrasonic applications is presented. The system, which incorporates dual Golay code matched filtering, is capable of 20-MHz processing rates with a signal-to-noise-ratio enhancement (SNRE) of 23 dB ov...
| Veröffentlicht in: | IEEE transactions on ultrasonics, ferroelectrics, and frequency control. - 1986. - 35(1988), 6 vom: 15., Seite 800-8 |
|---|---|
| 1. Verfasser: | |
| Weitere Verfasser: | |
| Format: | Aufsatz |
| Sprache: | English |
| Veröffentlicht: |
1988
|
| Zugriff auf das übergeordnete Werk: | IEEE transactions on ultrasonics, ferroelectrics, and frequency control |
| Schlagworte: | Journal Article |