Blood flow images by a SAW-based multigate Doppler system

Multigate operation of an ultrasound pulsed Doppler flowmeter, providing Doppler frequency detection in a number of adjacent sample volumes, is capable of displaying the instantaneous blood velocity distribution along the cross section of a sonified vessel. Real-time serial Doppler processing of 32...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on ultrasonics, ferroelectrics, and frequency control. - 1986. - 35(1988), 5 vom: 15., Seite 545-51
1. Verfasser: Tortoli, P (VerfasserIn)
Weitere Verfasser: Andreuccetti, F, Manes, G, Atzeni, C
Format: Aufsatz
Sprache:English
Veröffentlicht: 1988
Zugriff auf das übergeordnete Werk:IEEE transactions on ultrasonics, ferroelectrics, and frequency control
Schlagworte:Journal Article
LEADER 01000caa a22002652 4500
001 NLM17776550X
003 DE-627
005 20250209061426.0
007 tu
008 231223s1988 xx ||||| 00| ||eng c
028 5 2 |a pubmed25n0593.xml 
035 |a (DE-627)NLM17776550X 
035 |a (NLM)18290186 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Tortoli, P  |e verfasserin  |4 aut 
245 1 0 |a Blood flow images by a SAW-based multigate Doppler system 
264 1 |c 1988 
336 |a Text  |b txt  |2 rdacontent 
337 |a ohne Hilfsmittel zu benutzen  |b n  |2 rdamedia 
338 |a Band  |b nc  |2 rdacarrier 
500 |a Date Completed 02.10.2012 
500 |a Date Revised 21.02.2008 
500 |a published: Print 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a Multigate operation of an ultrasound pulsed Doppler flowmeter, providing Doppler frequency detection in a number of adjacent sample volumes, is capable of displaying the instantaneous blood velocity distribution along the cross section of a sonified vessel. Real-time serial Doppler processing of 32 range cells has been implemented in a novel system using fast spectral analysis based on surface-acoustic wave (SAW) dispersive filters. The basic architecture and first in vitro experiments were reported previously. The in vivo application of the system is described here, and images of human carotid artery and jugular vein are presented. Appropriate display formats are introduced to use the great amount of information known on spatial and temporal behavior of flow profiles. Digital postprocessing of spectral Doppler data allows velocity profiles to be displayed at selected times to correlate spatial and temporal evolution. A color code can be used to represent different velocity strengths. The potential application of the system to two-dimensional (2-D) flow imaging is discussed 
650 4 |a Journal Article 
700 1 |a Andreuccetti, F  |e verfasserin  |4 aut 
700 1 |a Manes, G  |e verfasserin  |4 aut 
700 1 |a Atzeni, C  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t IEEE transactions on ultrasonics, ferroelectrics, and frequency control  |d 1986  |g 35(1988), 5 vom: 15., Seite 545-51  |w (DE-627)NLM098181017  |x 1525-8955  |7 nnns 
773 1 8 |g volume:35  |g year:1988  |g number:5  |g day:15  |g pages:545-51 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_22 
912 |a GBV_ILN_24 
912 |a GBV_ILN_350 
951 |a AR 
952 |d 35  |j 1988  |e 5  |b 15  |h 545-51