In-vivo fetal ultrasound exposimetry

An instrument has been developed to measure the acoustic pressure field in vivo during an obstetric ultrasound examination. This provides for improved intensity values for exposure calculations, to assist in assessment of bioeffects. The ultrasonic field is sampled using a calibrated seven-element l...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on ultrasonics, ferroelectrics, and frequency control. - 1986. - 37(1990), 6 vom: 15., Seite 501-5
1. Verfasser: Daft, C W (VerfasserIn)
Weitere Verfasser: Siddiqi, T A, Fitting, D W, Meyer, R A, O'Brien, W R
Format: Aufsatz
Sprache:English
Veröffentlicht: 1990
Zugriff auf das übergeordnete Werk:IEEE transactions on ultrasonics, ferroelectrics, and frequency control
Schlagworte:Journal Article
LEADER 01000caa a22002652 4500
001 NLM177716754
003 DE-627
005 20250209060544.0
007 tu
008 231223s1990 xx ||||| 00| ||eng c
028 5 2 |a pubmed25n0592.xml 
035 |a (DE-627)NLM177716754 
035 |a (NLM)18285070 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Daft, C W  |e verfasserin  |4 aut 
245 1 0 |a In-vivo fetal ultrasound exposimetry 
264 1 |c 1990 
336 |a Text  |b txt  |2 rdacontent 
337 |a ohne Hilfsmittel zu benutzen  |b n  |2 rdamedia 
338 |a Band  |b nc  |2 rdacarrier 
500 |a Date Completed 02.10.2012 
500 |a Date Revised 20.02.2008 
500 |a published: Print 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a An instrument has been developed to measure the acoustic pressure field in vivo during an obstetric ultrasound examination. This provides for improved intensity values for exposure calculations, to assist in assessment of bioeffects. The ultrasonic field is sampled using a calibrated seven-element linear array hydrophone of poly(vinylidene difluoride) transducers, which is placed as close as possible to the ovary, embryo, or fetus using a vaginal approach. The RF signals from the hydrophone are digitized at 50 MHz, and the maximum amplitude waveform received in the examination is recorded. The output of the clinical B-scanner is calibrated by a measurement with the hydrophone in a water bath. From the hydrophone measurements, the in vivo I(SPTA), I(SPTP), and I(SPPA) are computed. Further analysis allows the frequency-dependent tissue attenuation to be assessed 
650 4 |a Journal Article 
700 1 |a Siddiqi, T A  |e verfasserin  |4 aut 
700 1 |a Fitting, D W  |e verfasserin  |4 aut 
700 1 |a Meyer, R A  |e verfasserin  |4 aut 
700 1 |a O'Brien, W R  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t IEEE transactions on ultrasonics, ferroelectrics, and frequency control  |d 1986  |g 37(1990), 6 vom: 15., Seite 501-5  |w (DE-627)NLM098181017  |x 1525-8955  |7 nnns 
773 1 8 |g volume:37  |g year:1990  |g number:6  |g day:15  |g pages:501-5 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_22 
912 |a GBV_ILN_24 
912 |a GBV_ILN_350 
951 |a AR 
952 |d 37  |j 1990  |e 6  |b 15  |h 501-5