Quantitative real-time imaging of myocardium based on ultrasonic integrated backscatter

The integrated backscatter calculation over the full, two-dimensional echocardiographic sector is implemented to produce images from closed-chest dogs. This new real-time integrated backscatter measurement system allows a continuous determination of integrated backscatter from all myocardial regions...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on ultrasonics, ferroelectrics, and frequency control. - 1986. - 36(1989), 4 vom: 15., Seite 466-70
1. Verfasser: Thomas, L J (VerfasserIn)
Weitere Verfasser: Barzilai, B, Perez, J E, Sobel, B E, Wickline, S A, Miller, J G
Format: Aufsatz
Sprache:English
Veröffentlicht: 1989
Zugriff auf das übergeordnete Werk:IEEE transactions on ultrasonics, ferroelectrics, and frequency control
Schlagworte:Journal Article
LEADER 01000naa a22002652 4500
001 NLM177716134
003 DE-627
005 20231223150831.0
007 tu
008 231223s1989 xx ||||| 00| ||eng c
028 5 2 |a pubmed24n0592.xml 
035 |a (DE-627)NLM177716134 
035 |a (NLM)18285008 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Thomas, L J  |e verfasserin  |4 aut 
245 1 0 |a Quantitative real-time imaging of myocardium based on ultrasonic integrated backscatter 
264 1 |c 1989 
336 |a Text  |b txt  |2 rdacontent 
337 |a ohne Hilfsmittel zu benutzen  |b n  |2 rdamedia 
338 |a Band  |b nc  |2 rdacarrier 
500 |a Date Completed 02.10.2012 
500 |a Date Revised 20.02.2008 
500 |a published: Print 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a The integrated backscatter calculation over the full, two-dimensional echocardiographic sector is implemented to produce images from closed-chest dogs. This new real-time integrated backscatter measurement system allows a continuous determination of integrated backscatter from all myocardial regions in the ultrasonic view. By replacing the conventional video processor in a commercial two-dimensional echocardiographic imager with this new real-time backscatter measurement system, it is possible to produce real-time two-dimensional images based on integrated backscatter 
650 4 |a Journal Article 
700 1 |a Barzilai, B  |e verfasserin  |4 aut 
700 1 |a Perez, J E  |e verfasserin  |4 aut 
700 1 |a Sobel, B E  |e verfasserin  |4 aut 
700 1 |a Wickline, S A  |e verfasserin  |4 aut 
700 1 |a Miller, J G  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t IEEE transactions on ultrasonics, ferroelectrics, and frequency control  |d 1986  |g 36(1989), 4 vom: 15., Seite 466-70  |w (DE-627)NLM098181017  |x 1525-8955  |7 nnns 
773 1 8 |g volume:36  |g year:1989  |g number:4  |g day:15  |g pages:466-70 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_22 
912 |a GBV_ILN_24 
912 |a GBV_ILN_350 
951 |a AR 
952 |d 36  |j 1989  |e 4  |b 15  |h 466-70