Three-dimensional geostatistical inversion of flowmeter and pumping test data

We jointly invert field data of flowmeter and multiple pumping tests in fully screened wells to estimate hydraulic conductivity using a geostatistical method. We use the steady-state drawdowns of pumping tests and the discharge profiles of flowmeter tests as our data in the inference. The discharge...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Ground water. - 1998. - 46(2008), 2 vom: 15. März, Seite 193-201
1. Verfasser: Li, Wei (VerfasserIn)
Weitere Verfasser: Englert, Andreas, Cirpka, Olaf A, Vereecken, Harry
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2008
Zugriff auf das übergeordnete Werk:Ground water
Schlagworte:Journal Article
LEADER 01000caa a22002652 4500
001 NLM177540931
003 DE-627
005 20250209051604.0
007 cr uuu---uuuuu
008 231223s2008 xx |||||o 00| ||eng c
024 7 |a 10.1111/j.1745-6584.2007.00419.x  |2 doi 
028 5 2 |a pubmed25n0592.xml 
035 |a (DE-627)NLM177540931 
035 |a (NLM)18266734 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Li, Wei  |e verfasserin  |4 aut 
245 1 0 |a Three-dimensional geostatistical inversion of flowmeter and pumping test data 
264 1 |c 2008 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 08.08.2008 
500 |a Date Revised 29.02.2008 
500 |a published: Print-Electronic 
500 |a Citation Status MEDLINE 
520 |a We jointly invert field data of flowmeter and multiple pumping tests in fully screened wells to estimate hydraulic conductivity using a geostatistical method. We use the steady-state drawdowns of pumping tests and the discharge profiles of flowmeter tests as our data in the inference. The discharge profiles need not be converted to absolute hydraulic conductivities. Consequently, we do not need measurements of depth-averaged hydraulic conductivity at well locations. The flowmeter profiles contain information about relative vertical distributions of hydraulic conductivity, while drawdown measurements of pumping tests provide information about horizontal fluctuation of the depth-averaged hydraulic conductivity. We apply the method to data obtained at the Krauthausen test site of the Forschungszentrum Jülich, Germany. The resulting estimate of our joint three-dimensional (3D) geostatistical inversion shows an improved 3D structure in comparison to the inversion of pumping test data only 
650 4 |a Journal Article 
700 1 |a Englert, Andreas  |e verfasserin  |4 aut 
700 1 |a Cirpka, Olaf A  |e verfasserin  |4 aut 
700 1 |a Vereecken, Harry  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Ground water  |d 1998  |g 46(2008), 2 vom: 15. März, Seite 193-201  |w (DE-627)NLM098182528  |x 1745-6584  |7 nnns 
773 1 8 |g volume:46  |g year:2008  |g number:2  |g day:15  |g month:03  |g pages:193-201 
856 4 0 |u http://dx.doi.org/10.1111/j.1745-6584.2007.00419.x  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_350 
951 |a AR 