Lung damage assessment from exposure to pulsed-wave ultrasound in the rabbit, mouse, and pig

The principal motivation of the study was to assess experimentally the question: "Is the MI (Mechanical Index) an equivalent or better indicator of nonthermal bioeffect risk than I(SPPA.3) (derated spatial peak, pulse average intensity)?" To evaluate this question, the experimental design...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on ultrasonics, ferroelectrics, and frequency control. - 1986. - 44(1997), 2 vom: 15., Seite 473-85
1. Verfasser: O'Brien, W R (VerfasserIn)
Weitere Verfasser: Zachary, J F
Format: Aufsatz
Sprache:English
Veröffentlicht: 1997
Zugriff auf das übergeordnete Werk:IEEE transactions on ultrasonics, ferroelectrics, and frequency control
Schlagworte:Journal Article
LEADER 01000caa a22002652 4500
001 NLM177324937
003 DE-627
005 20250209042603.0
007 tu
008 231223s1997 xx ||||| 00| ||eng c
028 5 2 |a pubmed25n0591.xml 
035 |a (DE-627)NLM177324937 
035 |a (NLM)18244145 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a O'Brien, W R  |e verfasserin  |4 aut 
245 1 0 |a Lung damage assessment from exposure to pulsed-wave ultrasound in the rabbit, mouse, and pig 
264 1 |c 1997 
336 |a Text  |b txt  |2 rdacontent 
337 |a ohne Hilfsmittel zu benutzen  |b n  |2 rdamedia 
338 |a Band  |b nc  |2 rdacarrier 
500 |a Date Completed 02.10.2012 
500 |a Date Revised 04.02.2008 
500 |a published: Print 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a The principal motivation of the study was to assess experimentally the question: "Is the MI (Mechanical Index) an equivalent or better indicator of nonthermal bioeffect risk than I(SPPA.3) (derated spatial peak, pulse average intensity)?" To evaluate this question, the experimental design consisted of a reproducible biological effect in order to provide a quantitative assessment of the effect. The specific biological effect used was lung damage and the species chosen was the rabbit. This work was initiated, in part, by a study in which lung hemorrhage was observed in 7-week old C3H mice for diagnostic-type, pulsed-wave ultrasound exposures, and, therefore, 6- to 7-week old C3H mice were used in this study as positive controls. Forty-seven adult New Zealand White male rabbits were exposed to a wide range of ultrasound amplitude conditions at center frequencies of 3 and 6 MHz with all temporal exposure variables held constant. A calibrated, commercial diagnostic ultrasound system was used as the ultrasound source with output levels exceeding, in some cases, permissible FDA levels. The MI was shown to be at least an equivalent, and in some cases, a better indicator of rabbit lung damage than either the I(SPPA.3) or p(r.3) (derated peak rarefactional pressure), thus answering the posed question positively. Further, in situ exposure conditions were estimated at the lung pleural surface (PS); the estimated in situ I(SPPA.PS) and p(r.PS) exposure conditions tracked lung damage no better than I(SPPA.3) and p(r.3), respectively, whereas the estimated in situ MI(PS) exposure condition was a slightly poorer predictor of lung damage than MI. Finally, the lungs of six adult crossbred pigs were exposed at the highest amplitude exposure levels permitted by a diagnostic ultrasound system (to prevent probe damage) at both frequencies; no lung damage was observed which suggests the possibility of a species dependency biological effect 
650 4 |a Journal Article 
700 1 |a Zachary, J F  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t IEEE transactions on ultrasonics, ferroelectrics, and frequency control  |d 1986  |g 44(1997), 2 vom: 15., Seite 473-85  |w (DE-627)NLM098181017  |x 1525-8955  |7 nnns 
773 1 8 |g volume:44  |g year:1997  |g number:2  |g day:15  |g pages:473-85 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_22 
912 |a GBV_ILN_24 
912 |a GBV_ILN_350 
951 |a AR 
952 |d 44  |j 1997  |e 2  |b 15  |h 473-85