SPICE model for lossy piezoceramic transducers
A transmission line equivalent circuit for piezoelectric transducers has been modified to provide modeling of lossy piezoceramic transducers. A lossy transmission line is used to model the mechanical losses. The equivalent circuit parameters are derived from analogies between electrical transmission...
Veröffentlicht in: | IEEE transactions on ultrasonics, ferroelectrics, and frequency control. - 1986. - 44(1997), 1 vom: 15., Seite 60-6 |
---|---|
1. Verfasser: | |
Weitere Verfasser: | , , , |
Format: | Aufsatz |
Sprache: | English |
Veröffentlicht: |
1997
|
Zugriff auf das übergeordnete Werk: | IEEE transactions on ultrasonics, ferroelectrics, and frequency control |
Schlagworte: | Journal Article |
Zusammenfassung: | A transmission line equivalent circuit for piezoelectric transducers has been modified to provide modeling of lossy piezoceramic transducers. A lossy transmission line is used to model the mechanical losses. The equivalent circuit parameters are derived from analogies between electrical transmission lines and acoustic wave propagation. Implementation of the equivalent circuit model in SPICE is shown. Simulations and measurements in the time and frequency domain of a low-Q material and a multilayered ultrasonic sensor using a low-Q piezoceramic transducer are presented |
---|---|
Beschreibung: | Date Completed 02.10.2012 Date Revised 04.02.2008 published: Print Citation Status PubMed-not-MEDLINE |