Transient response following frequency or amplitude switching in a cesium beam tube

The transient responses of an optically pumped cesium beam tube to square wave frequency and amplitude modulation is considered. The frequency transient is computed assuming a phase difference phi of either 0 or pi between the two oscillatory fields. We present theoretical and experimental data show...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on ultrasonics, ferroelectrics, and frequency control. - 1986. - 46(1999), 4 vom: 28., Seite 861-6
1. Verfasser: Hamouda, F (VerfasserIn)
Weitere Verfasser: Audoin, C, Chassagne, L, Barillet, R
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 1999
Zugriff auf das übergeordnete Werk:IEEE transactions on ultrasonics, ferroelectrics, and frequency control
Schlagworte:Journal Article
LEADER 01000caa a22002652 4500
001 NLM177271523
003 DE-627
005 20250209041308.0
007 cr uuu---uuuuu
008 231223s1999 xx |||||o 00| ||eng c
024 7 |a 10.1109/58.775651  |2 doi 
028 5 2 |a pubmed25n0591.xml 
035 |a (DE-627)NLM177271523 
035 |a (NLM)18238489 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Hamouda, F  |e verfasserin  |4 aut 
245 1 0 |a Transient response following frequency or amplitude switching in a cesium beam tube 
264 1 |c 1999 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 02.10.2012 
500 |a Date Revised 01.02.2008 
500 |a published: Print 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a The transient responses of an optically pumped cesium beam tube to square wave frequency and amplitude modulation is considered. The frequency transient is computed assuming a phase difference phi of either 0 or pi between the two oscillatory fields. We present theoretical and experimental data showing that, contrary to the frequency transient, the amplitude transient depends on the direction of switching. The knowledge of this property is useful for the design of the servo-loop controlling the amplitude of the microwave signal applied to the atomic resonator. A justification of this asymmetrical behavior is given. Experimental results confirm the theoretical predictions in the case phi=pi 
650 4 |a Journal Article 
700 1 |a Audoin, C  |e verfasserin  |4 aut 
700 1 |a Chassagne, L  |e verfasserin  |4 aut 
700 1 |a Barillet, R  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t IEEE transactions on ultrasonics, ferroelectrics, and frequency control  |d 1986  |g 46(1999), 4 vom: 28., Seite 861-6  |w (DE-627)NLM098181017  |x 1525-8955  |7 nnns 
773 1 8 |g volume:46  |g year:1999  |g number:4  |g day:28  |g pages:861-6 