Quantitative estimation of thermal contact conductance of a real front-end component at SPring-8 front-ends

The thermal contact conductance (TCC) of a real front-end component at SPring-8 has been quantitatively estimated by comparing the results of experiments with those of finite-element analyses. In this paper one of the methods of predicting the TCC of a real instrument is presented. A metal filter as...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Journal of synchrotron radiation. - 1994. - 15(2008), Pt 1 vom: 01. Jan., Seite 1-7
1. Verfasser: Sano, Mutsumi (VerfasserIn)
Weitere Verfasser: Takahashi, Sunao, Mochizuki, Tetsuro, Watanabe, Atsuo, Oura, Masaki, Kitamura, Hideo
Format: Aufsatz
Sprache:English
Veröffentlicht: 2008
Zugriff auf das übergeordnete Werk:Journal of synchrotron radiation
Schlagworte:Journal Article
LEADER 01000naa a22002652 4500
001 NLM175911800
003 DE-627
005 20231223143023.0
007 tu
008 231223s2008 xx ||||| 00| ||eng c
028 5 2 |a pubmed24n0586.xml 
035 |a (DE-627)NLM175911800 
035 |a (NLM)18097071 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Sano, Mutsumi  |e verfasserin  |4 aut 
245 1 0 |a Quantitative estimation of thermal contact conductance of a real front-end component at SPring-8 front-ends 
264 1 |c 2008 
336 |a Text  |b txt  |2 rdacontent 
337 |a ohne Hilfsmittel zu benutzen  |b n  |2 rdamedia 
338 |a Band  |b nc  |2 rdacarrier 
500 |a Date Completed 17.03.2008 
500 |a Date Revised 21.12.2007 
500 |a published: Print-Electronic 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a The thermal contact conductance (TCC) of a real front-end component at SPring-8 has been quantitatively estimated by comparing the results of experiments with those of finite-element analyses. In this paper one of the methods of predicting the TCC of a real instrument is presented. A metal filter assembly, which is an indirect-cooling instrument, was selected for the estimation of the TCC. The temperature of the metal filter assembly for the maximum heat load of synchrotron radiation was calculated from the TCC that is expected under normal conditions. This study contributes towards the ongoing research program being conducted to investigate the real thermal limitation of all front-end high-heat-load components 
650 4 |a Journal Article 
700 1 |a Takahashi, Sunao  |e verfasserin  |4 aut 
700 1 |a Mochizuki, Tetsuro  |e verfasserin  |4 aut 
700 1 |a Watanabe, Atsuo  |e verfasserin  |4 aut 
700 1 |a Oura, Masaki  |e verfasserin  |4 aut 
700 1 |a Kitamura, Hideo  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Journal of synchrotron radiation  |d 1994  |g 15(2008), Pt 1 vom: 01. Jan., Seite 1-7  |w (DE-627)NLM09824129X  |x 1600-5775  |7 nnns 
773 1 8 |g volume:15  |g year:2008  |g number:Pt 1  |g day:01  |g month:01  |g pages:1-7 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_40 
912 |a GBV_ILN_350 
912 |a GBV_ILN_2005 
951 |a AR 
952 |d 15  |j 2008  |e Pt 1  |b 01  |c 01  |h 1-7