Secondary hospital wastewater detoxification and disinfection by advanced oxidation processes

Secondary hospital wastewater treatment was investigated as an alternative to detoxification and disinfection after anaerobic digestion in a hospital located in southern Brazil. Tertiary and secondary effluents were assessed by general parameters. The use of advanced oxidation processes (UV/O3 and U...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Environmental technology. - 1993. - 28(2007), 10 vom: 20. Okt., Seite 1135-43
1. Verfasser: Machado, E L (VerfasserIn)
Weitere Verfasser: Kist, L T, Schmidt, R, Hoeltz, J M, Dalberto, D, Alcayaga, E L A
Format: Aufsatz
Sprache:English
Veröffentlicht: 2007
Zugriff auf das übergeordnete Werk:Environmental technology
Schlagworte:Journal Article Research Support, Non-U.S. Gov't Industrial Waste titanium dioxide 15FIX9V2JP Ozone 66H7ZZK23N Titanium D1JT611TNE
LEADER 01000naa a22002652 4500
001 NLM174709951
003 DE-627
005 20231223140522.0
007 tu
008 231223s2007 xx ||||| 00| ||eng c
028 5 2 |a pubmed24n0582.xml 
035 |a (DE-627)NLM174709951 
035 |a (NLM)17970520 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Machado, E L  |e verfasserin  |4 aut 
245 1 0 |a Secondary hospital wastewater detoxification and disinfection by advanced oxidation processes 
264 1 |c 2007 
336 |a Text  |b txt  |2 rdacontent 
337 |a ohne Hilfsmittel zu benutzen  |b n  |2 rdamedia 
338 |a Band  |b nc  |2 rdacarrier 
500 |a Date Completed 28.01.2008 
500 |a Date Revised 21.11.2013 
500 |a published: Print 
500 |a Citation Status MEDLINE 
520 |a Secondary hospital wastewater treatment was investigated as an alternative to detoxification and disinfection after anaerobic digestion in a hospital located in southern Brazil. Tertiary and secondary effluents were assessed by general parameters. The use of advanced oxidation processes (UV/O3 and UV/TiO2/O3) showed potential capacity for disinfection and detoxification of wastewater effluents. The UV/TiO2/O3 method yielded the best results, decreasing toxicity of EC50 = 65 to nontoxic levels, also reducing MPN/100ml of 1.1 x 10(6) to values less than 2 and increasing wastewater biodegradability. The low energetic consumption of the proposed UV/TiO2/O3 method can be considered operationally advantageous 
650 4 |a Journal Article 
650 4 |a Research Support, Non-U.S. Gov't 
650 7 |a Industrial Waste  |2 NLM 
650 7 |a titanium dioxide  |2 NLM 
650 7 |a 15FIX9V2JP  |2 NLM 
650 7 |a Ozone  |2 NLM 
650 7 |a 66H7ZZK23N  |2 NLM 
650 7 |a Titanium  |2 NLM 
650 7 |a D1JT611TNE  |2 NLM 
700 1 |a Kist, L T  |e verfasserin  |4 aut 
700 1 |a Schmidt, R  |e verfasserin  |4 aut 
700 1 |a Hoeltz, J M  |e verfasserin  |4 aut 
700 1 |a Dalberto, D  |e verfasserin  |4 aut 
700 1 |a Alcayaga, E L A  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Environmental technology  |d 1993  |g 28(2007), 10 vom: 20. Okt., Seite 1135-43  |w (DE-627)NLM098202545  |x 1479-487X  |7 nnns 
773 1 8 |g volume:28  |g year:2007  |g number:10  |g day:20  |g month:10  |g pages:1135-43 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_350 
951 |a AR 
952 |d 28  |j 2007  |e 10  |b 20  |c 10  |h 1135-43