Incomplete oxidation of ethylenediaminetetraacetic acid in chemical oxygen demand analysis

Ethylenediaminetetraacetic acid (EDTA) was found to incompletely oxidize in chemical oxygen demand (COD) analysis, leading to incorrect COD values for water samples containing relatively large amounts of EDTA. The degree of oxidation depended on the oxidant used, its concentration, and the length of...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Water environment research : a research publication of the Water Environment Federation. - 1998. - 79(2007), 9 vom: 15. Sept., Seite 1043-9
1. Verfasser: Anderson, James E (VerfasserIn)
Weitere Verfasser: Mueller, Sherry A, Kim, Byung R
Format: Aufsatz
Sprache:English
Veröffentlicht: 2007
Zugriff auf das übergeordnete Werk:Water environment research : a research publication of the Water Environment Federation
Schlagworte:Journal Article Chelating Agents Edetic Acid 9G34HU7RV0 Oxygen S88TT14065
LEADER 01000caa a22002652 4500
001 NLM174138423
003 DE-627
005 20250208180653.0
007 tu
008 231223s2007 xx ||||| 00| ||eng c
028 5 2 |a pubmed25n0581.xml 
035 |a (DE-627)NLM174138423 
035 |a (NLM)17910374 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Anderson, James E  |e verfasserin  |4 aut 
245 1 0 |a Incomplete oxidation of ethylenediaminetetraacetic acid in chemical oxygen demand analysis 
264 1 |c 2007 
336 |a Text  |b txt  |2 rdacontent 
337 |a ohne Hilfsmittel zu benutzen  |b n  |2 rdamedia 
338 |a Band  |b nc  |2 rdacarrier 
500 |a Date Completed 04.01.2008 
500 |a Date Revised 23.09.2019 
500 |a published: Print 
500 |a Citation Status MEDLINE 
520 |a Ethylenediaminetetraacetic acid (EDTA) was found to incompletely oxidize in chemical oxygen demand (COD) analysis, leading to incorrect COD values for water samples containing relatively large amounts of EDTA. The degree of oxidation depended on the oxidant used, its concentration, and the length of digestion. The COD concentrations measured using COD vials with a potassium dichromate concentration of 0.10 N (after dilution by sample and sulfuric acid) were near theoretical oxygen demand values. However, COD measured with dichromate concentrations of 0.010 N and 0.0022 N were 30 to 40% lower than theoretical oxygen demand values. Similarly, lower COD values were observed with manganic sulfate as oxidant at 0.011 N. Extended digestion yielded somewhat higher COD values, suggesting incomplete and slower oxidation of EDTA, as a result of lower oxidant concentrations. For wastewater in which EDTA is a large fraction of COD, accurate COD measurement may not be achieved with methods using dichromate concentrations less than 0.1 N 
650 4 |a Journal Article 
650 7 |a Chelating Agents  |2 NLM 
650 7 |a Edetic Acid  |2 NLM 
650 7 |a 9G34HU7RV0  |2 NLM 
650 7 |a Oxygen  |2 NLM 
650 7 |a S88TT14065  |2 NLM 
700 1 |a Mueller, Sherry A  |e verfasserin  |4 aut 
700 1 |a Kim, Byung R  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Water environment research : a research publication of the Water Environment Federation  |d 1998  |g 79(2007), 9 vom: 15. Sept., Seite 1043-9  |w (DE-627)NLM098214292  |x 1061-4303  |7 nnns 
773 1 8 |g volume:79  |g year:2007  |g number:9  |g day:15  |g month:09  |g pages:1043-9 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_350 
951 |a AR 
952 |d 79  |j 2007  |e 9  |b 15  |c 09  |h 1043-9