J-modulated ADEQUATE experiments using different kinds of refocusing pulses

(c) 2007 John Wiley & Sons, Ltd.

Bibliographische Detailangaben
Veröffentlicht in:Magnetic resonance in chemistry : MRC. - 1985. - 45(2007), 10 vom: 30. Okt., Seite 889-94
1. Verfasser: Thiele, Christina M (VerfasserIn)
Weitere Verfasser: Bermel, Wolfgang
Format: Aufsatz
Sprache:English
Veröffentlicht: 2007
Zugriff auf das übergeordnete Werk:Magnetic resonance in chemistry : MRC
Schlagworte:Journal Article Research Support, Non-U.S. Gov't
LEADER 01000naa a22002652 4500
001 NLM172406889
003 DE-627
005 20231223131731.0
007 tu
008 231223s2007 xx ||||| 00| ||eng c
028 5 2 |a pubmed24n0575.xml 
035 |a (DE-627)NLM172406889 
035 |a (NLM)17729234 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Thiele, Christina M  |e verfasserin  |4 aut 
245 1 0 |a J-modulated ADEQUATE experiments using different kinds of refocusing pulses 
264 1 |c 2007 
336 |a Text  |b txt  |2 rdacontent 
337 |a ohne Hilfsmittel zu benutzen  |b n  |2 rdamedia 
338 |a Band  |b nc  |2 rdacarrier 
500 |a Date Completed 28.12.2007 
500 |a Date Revised 04.09.2007 
500 |a published: Print 
500 |a Citation Status MEDLINE 
520 |a (c) 2007 John Wiley & Sons, Ltd. 
520 |a Owing to the recent developments concerning residual dipolar couplings (RDCs), the interest in methods for the accurate determination of coupling constants is renascenting. We intended to use the J-modulated ADEQUATE experiment by Kövér et al. for the measurement of (13)C - (13)C coupling constants at natural abundance. The use of adiabatic composite chirp pulses instead of the conventional 180 degrees pulses, which compensate for the offset dependence of (13)C 180 degrees pulses, led to irregularities of the line shapes in the indirect dimension causing deviations of the extracted coupling constants. This behaviour was attributed to coupling evolution, during the time of the adiabatic pulse (2 ms), in the J-modulation spin echo. The replacement of this pulse by different kinds of refocusing pulses indicated that a pair of BIPs (broadband inversion pulses), which behave only partially adiabatic, leads to correct line shapes and coupling constants conserving the good sensitivity obtained with adiabatic pulses 
650 4 |a Journal Article 
650 4 |a Research Support, Non-U.S. Gov't 
700 1 |a Bermel, Wolfgang  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Magnetic resonance in chemistry : MRC  |d 1985  |g 45(2007), 10 vom: 30. Okt., Seite 889-94  |w (DE-627)NLM098179667  |x 1097-458X  |7 nnns 
773 1 8 |g volume:45  |g year:2007  |g number:10  |g day:30  |g month:10  |g pages:889-94 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_350 
951 |a AR 
952 |d 45  |j 2007  |e 10  |b 30  |c 10  |h 889-94