XAS and XMCD under high magnetic field and low temperature on the energy-dispersive beamline of the ESRF

The present paper demonstrates the feasibility of X-ray absorption spectroscopy (XAS) and X-ray magnetic circular dichroism (XMCD) under high magnetic fields up to 26 T and low temperatures down to 5 K on the ID24 energy-dispersive XAS beamline of the ESRF. The pulsed magnetic field set-up, entirely...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Journal of synchrotron radiation. - 1994. - 14(2007), Pt 5 vom: 25. Sept., Seite 409-15
1. Verfasser: Mathon, O (VerfasserIn)
Weitere Verfasser: van der Linden, P, Neisius, T, Sikora, M, Michalik, J M, Ponchut, C, De Teresa, J M, Pascarelli, S
Format: Aufsatz
Sprache:English
Veröffentlicht: 2007
Zugriff auf das übergeordnete Werk:Journal of synchrotron radiation
Schlagworte:Journal Article Research Support, Non-U.S. Gov't
LEADER 01000naa a22002652 4500
001 NLM172296315
003 DE-627
005 20231223131507.0
007 tu
008 231223s2007 xx ||||| 00| ||eng c
028 5 2 |a pubmed24n0574.xml 
035 |a (DE-627)NLM172296315 
035 |a (NLM)17717382 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Mathon, O  |e verfasserin  |4 aut 
245 1 0 |a XAS and XMCD under high magnetic field and low temperature on the energy-dispersive beamline of the ESRF 
264 1 |c 2007 
336 |a Text  |b txt  |2 rdacontent 
337 |a ohne Hilfsmittel zu benutzen  |b n  |2 rdamedia 
338 |a Band  |b nc  |2 rdacarrier 
500 |a Date Completed 24.10.2007 
500 |a Date Revised 24.08.2007 
500 |a published: Print-Electronic 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a The present paper demonstrates the feasibility of X-ray absorption spectroscopy (XAS) and X-ray magnetic circular dichroism (XMCD) under high magnetic fields up to 26 T and low temperatures down to 5 K on the ID24 energy-dispersive XAS beamline of the ESRF. The pulsed magnetic field set-up, entirely developed at the ESRF, is described as well as the beamline set-up, the synchronization and the measurement procedure. It allows field strengths up to 30 T. Finally, as an example, we report a recent XMCD study at the Re L2 and L3 absorption edges of the double perovskite Sr2CrReO(6) 
650 4 |a Journal Article 
650 4 |a Research Support, Non-U.S. Gov't 
700 1 |a van der Linden, P  |e verfasserin  |4 aut 
700 1 |a Neisius, T  |e verfasserin  |4 aut 
700 1 |a Sikora, M  |e verfasserin  |4 aut 
700 1 |a Michalik, J M  |e verfasserin  |4 aut 
700 1 |a Ponchut, C  |e verfasserin  |4 aut 
700 1 |a De Teresa, J M  |e verfasserin  |4 aut 
700 1 |a Pascarelli, S  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Journal of synchrotron radiation  |d 1994  |g 14(2007), Pt 5 vom: 25. Sept., Seite 409-15  |w (DE-627)NLM09824129X  |x 1600-5775  |7 nnns 
773 1 8 |g volume:14  |g year:2007  |g number:Pt 5  |g day:25  |g month:09  |g pages:409-15 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_40 
912 |a GBV_ILN_350 
912 |a GBV_ILN_2005 
951 |a AR 
952 |d 14  |j 2007  |e Pt 5  |b 25  |c 09  |h 409-15