Wastewater infiltration percolation for water reuse and receiving body protection : thirteen years' experience in Spain

Infiltration percolation (IP) is an extensive technology to treat primary or secondary effluents of small and middle size communities before reuse or disposal to sensitive receiving bodies. Thirteen years of implementation of IP in Spain has highlighted the necessity to abide by defined design and c...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Water science and technology : a journal of the International Association on Water Pollution Research. - 1986. - 55(2007), 7 vom: 11., Seite 227-34
1. Verfasser: Brissaud, F (VerfasserIn)
Weitere Verfasser: Salgot, M, Folch, M, Auset, M, Huertas, E, Torrens, A
Format: Aufsatz
Sprache:English
Veröffentlicht: 2007
Zugriff auf das übergeordnete Werk:Water science and technology : a journal of the International Association on Water Pollution Research
Schlagworte:Journal Article Water 059QF0KO0R
LEADER 01000naa a22002652 4500
001 NLM170326217
003 DE-627
005 20231223123250.0
007 tu
008 231223s2007 xx ||||| 00| ||eng c
028 5 2 |a pubmed24n0568.xml 
035 |a (DE-627)NLM170326217 
035 |a (NLM)17506442 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Brissaud, F  |e verfasserin  |4 aut 
245 1 0 |a Wastewater infiltration percolation for water reuse and receiving body protection  |b thirteen years' experience in Spain 
264 1 |c 2007 
336 |a Text  |b txt  |2 rdacontent 
337 |a ohne Hilfsmittel zu benutzen  |b n  |2 rdamedia 
338 |a Band  |b nc  |2 rdacarrier 
500 |a Date Completed 13.06.2007 
500 |a Date Revised 17.09.2019 
500 |a published: Print 
500 |a Citation Status MEDLINE 
520 |a Infiltration percolation (IP) is an extensive technology to treat primary or secondary effluents of small and middle size communities before reuse or disposal to sensitive receiving bodies. Thirteen years of implementation of IP in Spain has highlighted the necessity to abide by defined design and construction rules and operation conditions in order to achieve consistently the treatment objectives and guarantee a long lasting treatment capacity. From this experience, high care should be taken of (i) the characteristics of the sand constituting the filter, (ii) the drainage conditions, (iii) the influent spreading over the infiltration surface and (iv) the risks related to recurrent overloading. Simple monitoring measures are suggested in order to improve the reliability of IP plants 
650 4 |a Journal Article 
650 7 |a Water  |2 NLM 
650 7 |a 059QF0KO0R  |2 NLM 
700 1 |a Salgot, M  |e verfasserin  |4 aut 
700 1 |a Folch, M  |e verfasserin  |4 aut 
700 1 |a Auset, M  |e verfasserin  |4 aut 
700 1 |a Huertas, E  |e verfasserin  |4 aut 
700 1 |a Torrens, A  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Water science and technology : a journal of the International Association on Water Pollution Research  |d 1986  |g 55(2007), 7 vom: 11., Seite 227-34  |w (DE-627)NLM098149431  |x 0273-1223  |7 nnns 
773 1 8 |g volume:55  |g year:2007  |g number:7  |g day:11  |g pages:227-34 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_350 
951 |a AR 