|
|
|
|
LEADER |
01000naa a22002652 4500 |
001 |
NLM168742527 |
003 |
DE-627 |
005 |
20231223115805.0 |
007 |
tu |
008 |
231223s2007 xx ||||| 00| ||eng c |
028 |
5 |
2 |
|a pubmed24n0563.xml
|
035 |
|
|
|a (DE-627)NLM168742527
|
035 |
|
|
|a (NLM)17335477
|
040 |
|
|
|a DE-627
|b ger
|c DE-627
|e rakwb
|
041 |
|
|
|a eng
|
100 |
1 |
|
|a West, Michael R
|e verfasserin
|4 aut
|
245 |
1 |
0 |
|a On the use and error of approximation in the Domenico (1987) solution
|
264 |
|
1 |
|c 2007
|
336 |
|
|
|a Text
|b txt
|2 rdacontent
|
337 |
|
|
|a ohne Hilfsmittel zu benutzen
|b n
|2 rdamedia
|
338 |
|
|
|a Band
|b nc
|2 rdacarrier
|
500 |
|
|
|a Date Completed 11.05.2007
|
500 |
|
|
|a Date Revised 29.08.2012
|
500 |
|
|
|a published: Print
|
500 |
|
|
|a CommentIn: Ground Water. 2009 Jan-Feb;47(1):5-6; discussion 6-7. - PMID 18657119
|
500 |
|
|
|a Citation Status MEDLINE
|
520 |
|
|
|a A mathematical solution for solute transport in a three-dimensional porous medium with a patch source under steady-state, uniform ground water flow conditions was developed by Domenico (1987). The solution derivation strategy used an approximate approach to solve the boundary value problem, resulting in a nonexact solution. Variations of the Domenico (1987) solution are incorporated into the software programs BIOSCREEN and BIOCHLOR, which are frequently used to evaluate subsurface contaminant transport problems. This article mathematically elucidates the error in the approximation and presents simulations that compare different versions of the Domenico (1987) solution to an exact analytical solution to demonstrate the potential error inherent in the approximate expressions. Results suggest that the accuracy of the approximate solutions is highly variable and dependent on the selection of input parameters. For solute transport in a medium-grained sand aquifer, the Domenico (1987) solution underpredicts solute concentrations along the centerline of the plume by as much as 80% depending on the case of interest. Increasing the dispersivity, time, or dimensionality of the system leads to increased error. Because more accurate exact analytical solutions exist, we suggest that the Domenico (1987) solution, and its predecessor and successor approximate solutions, need not be employed as the basis for screening tools at contaminated sites
|
650 |
|
4 |
|a Journal Article
|
650 |
|
4 |
|a Research Support, Non-U.S. Gov't
|
650 |
|
7 |
|a Water Pollutants
|2 NLM
|
700 |
1 |
|
|a Kueper, Bernard H
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Ungs, Michael J
|e verfasserin
|4 aut
|
773 |
0 |
8 |
|i Enthalten in
|t Ground water
|d 1979
|g 45(2007), 2 vom: 01. März, Seite 126-35
|w (DE-627)NLM098182528
|x 1745-6584
|7 nnns
|
773 |
1 |
8 |
|g volume:45
|g year:2007
|g number:2
|g day:01
|g month:03
|g pages:126-35
|
912 |
|
|
|a GBV_USEFLAG_A
|
912 |
|
|
|a SYSFLAG_A
|
912 |
|
|
|a GBV_NLM
|
912 |
|
|
|a GBV_ILN_350
|
951 |
|
|
|a AR
|
952 |
|
|
|d 45
|j 2007
|e 2
|b 01
|c 03
|h 126-35
|