Fast tomography using quasi-monochromatic undulator radiation

A beamline with a helical undulator has been used without a monochromator for fast high-resolution tomographic imaging with an X-ray energy of 12.4-16.5 keV and an energy bandwidth of 2-3%. The X-ray beam was expanded with two mirrors to 12 mm x 4 mm. The X-ray field was made uniform by a diffuser....

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Journal of synchrotron radiation. - 1994. - 13(2006), Pt 5 vom: 29. Sept., Seite 403-7
1. Verfasser: Uesugi, Kentaro (VerfasserIn)
Weitere Verfasser: Sera, Toshihiro, Yagi, Naoto
Format: Aufsatz
Sprache:English
Veröffentlicht: 2006
Zugriff auf das übergeordnete Werk:Journal of synchrotron radiation
Schlagworte:Journal Article Contrast Media Polymers
LEADER 01000naa a22002652 4500
001 NLM164919910
003 DE-627
005 20231223103601.0
007 tu
008 231223s2006 xx ||||| 00| ||eng c
028 5 2 |a pubmed24n0550.xml 
035 |a (DE-627)NLM164919910 
035 |a (NLM)16924137 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Uesugi, Kentaro  |e verfasserin  |4 aut 
245 1 0 |a Fast tomography using quasi-monochromatic undulator radiation 
264 1 |c 2006 
336 |a Text  |b txt  |2 rdacontent 
337 |a ohne Hilfsmittel zu benutzen  |b n  |2 rdamedia 
338 |a Band  |b nc  |2 rdacarrier 
500 |a Date Completed 20.11.2006 
500 |a Date Revised 24.11.2016 
500 |a published: Print-Electronic 
500 |a Citation Status MEDLINE 
520 |a A beamline with a helical undulator has been used without a monochromator for fast high-resolution tomographic imaging with an X-ray energy of 12.4-16.5 keV and an energy bandwidth of 2-3%. The X-ray beam was expanded with two mirrors to 12 mm x 4 mm. The X-ray field was made uniform by a diffuser. The detector pixel size was 9.9 microm x 9.9 microm. At the highest speed, a 180 degrees scan was completed in 6 s with 454 projections. Beam-hardening effects were not significant. This technique may be useful in studying time-dependent structural changes of soft materials such as polymers and biological samples 
650 4 |a Journal Article 
650 7 |a Contrast Media  |2 NLM 
650 7 |a Polymers  |2 NLM 
700 1 |a Sera, Toshihiro  |e verfasserin  |4 aut 
700 1 |a Yagi, Naoto  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Journal of synchrotron radiation  |d 1994  |g 13(2006), Pt 5 vom: 29. Sept., Seite 403-7  |w (DE-627)NLM09824129X  |x 1600-5775  |7 nnns 
773 1 8 |g volume:13  |g year:2006  |g number:Pt 5  |g day:29  |g month:09  |g pages:403-7 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_40 
912 |a GBV_ILN_350 
912 |a GBV_ILN_2005 
951 |a AR 
952 |d 13  |j 2006  |e Pt 5  |b 29  |c 09  |h 403-7