High-resolution ultrasonic imaging using fast two-dimensional homomorphic filtering

A new method for two-dimensional deconvolution of medical ultrasonic images is presented. The spatial resolution of the deconvolved images is much higher compared to the common images of the fundamental and second harmonic. The deconvolution also results in a more distinct speckle pattern. Unlike th...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on ultrasonics, ferroelectrics, and frequency control. - 1999. - 53(2006), 8 vom: 15. Aug., Seite 1440-8
1. Verfasser: Jirík, Radovan (VerfasserIn)
Weitere Verfasser: Taxt, Torfinn
Format: Aufsatz
Sprache:English
Veröffentlicht: 2006
Zugriff auf das übergeordnete Werk:IEEE transactions on ultrasonics, ferroelectrics, and frequency control
Schlagworte:Evaluation Study Journal Article Research Support, Non-U.S. Gov't
LEADER 01000caa a22002652 4500
001 NLM164898344
003 DE-627
005 20250207134105.0
007 tu
008 231223s2006 xx ||||| 00| ||eng c
028 5 2 |a pubmed25n0550.xml 
035 |a (DE-627)NLM164898344 
035 |a (NLM)16921896 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Jirík, Radovan  |e verfasserin  |4 aut 
245 1 0 |a High-resolution ultrasonic imaging using fast two-dimensional homomorphic filtering 
264 1 |c 2006 
336 |a Text  |b txt  |2 rdacontent 
337 |a ohne Hilfsmittel zu benutzen  |b n  |2 rdamedia 
338 |a Band  |b nc  |2 rdacarrier 
500 |a Date Completed 12.09.2006 
500 |a Date Revised 10.12.2019 
500 |a published: Print 
500 |a Citation Status MEDLINE 
520 |a A new method for two-dimensional deconvolution of medical ultrasonic images is presented. The spatial resolution of the deconvolved images is much higher compared to the common images of the fundamental and second harmonic. The deconvolution also results in a more distinct speckle pattern. Unlike the most published deconvolution algorithms for ultrasonic images, the presented technique can be implemented using currently available hardware in real-time imaging, with a rate up to 50 frames per second. This makes it attractive for application in the current ultrasound scanners. The algorithm is based on two-dimensional homomorphic deconvolution with simplified assumptions about the point spread function. Broadband radio frequency image data are deconvolved instead of common fundamental harmonic data. Thus, information of both the first and second harmonics is used. The method was validated on image data recorded from a tissue-mimicking phantom and on clinical image data 
650 4 |a Evaluation Study 
650 4 |a Journal Article 
650 4 |a Research Support, Non-U.S. Gov't 
700 1 |a Taxt, Torfinn  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t IEEE transactions on ultrasonics, ferroelectrics, and frequency control  |d 1999  |g 53(2006), 8 vom: 15. Aug., Seite 1440-8  |w (DE-627)NLM098181017  |x 0885-3010  |7 nnns 
773 1 8 |g volume:53  |g year:2006  |g number:8  |g day:15  |g month:08  |g pages:1440-8 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_22 
912 |a GBV_ILN_24 
912 |a GBV_ILN_350 
951 |a AR 
952 |d 53  |j 2006  |e 8  |b 15  |c 08  |h 1440-8