Continuous geodetic time-transfer analysis methods

We address two issues that limit the quality of time and frequency transfer by carrier phase measurements from the Global Positioning System (GPS). The first issue is related to inconsistencies between code and phase observations. We describe and classify several types of events that can cause incon...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on ultrasonics, ferroelectrics, and frequency control. - 1999. - 53(2006), 7 vom: 29. Juli, Seite 1250-9
1. Verfasser: Dach, Rolf (VerfasserIn)
Weitere Verfasser: Schildknecht, Thomas, Hugentobler, Urs, Bernier, Laurent-Guy, Dudle, Gregor
Format: Aufsatz
Sprache:English
Veröffentlicht: 2006
Zugriff auf das übergeordnete Werk:IEEE transactions on ultrasonics, ferroelectrics, and frequency control
Schlagworte:Journal Article
LEADER 01000caa a22002652 4500
001 NLM164591958
003 DE-627
005 20250207124813.0
007 tu
008 231223s2006 xx ||||| 00| ||eng c
028 5 2 |a pubmed25n0549.xml 
035 |a (DE-627)NLM164591958 
035 |a (NLM)16889332 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Dach, Rolf  |e verfasserin  |4 aut 
245 1 0 |a Continuous geodetic time-transfer analysis methods 
264 1 |c 2006 
336 |a Text  |b txt  |2 rdacontent 
337 |a ohne Hilfsmittel zu benutzen  |b n  |2 rdamedia 
338 |a Band  |b nc  |2 rdacarrier 
500 |a Date Completed 05.09.2006 
500 |a Date Revised 17.09.2019 
500 |a published: Print 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a We address two issues that limit the quality of time and frequency transfer by carrier phase measurements from the Global Positioning System (GPS). The first issue is related to inconsistencies between code and phase observations. We describe and classify several types of events that can cause inconsistencies and observe that some of them are related to the internal clock of the GPS receiver. Strategies to detect and overcome time-code inconsistencies have been developed and implemented into the Bernese GPS Software package. For the moment, only inconsistencies larger than the 20 ns code measurement noise level can be detected automatically. The second issue is related to discontinuities at the day boundaries that stem from the processing of the data in daily batches. Two new methods are discussed: clock handover and ambiguity stacking. The two approaches are tested on data obtained from a network of stations, and the results are compared with an independent time-transfer method. Both methods improve the stability of the transfer for short averaging times, but there is no benefit for averaging times longer than 8 days. We show that continuous solutions are sufficiently robust against modeling and preprocessing errors to prevent the solution from accumulating a permanent bias 
650 4 |a Journal Article 
700 1 |a Schildknecht, Thomas  |e verfasserin  |4 aut 
700 1 |a Hugentobler, Urs  |e verfasserin  |4 aut 
700 1 |a Bernier, Laurent-Guy  |e verfasserin  |4 aut 
700 1 |a Dudle, Gregor  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t IEEE transactions on ultrasonics, ferroelectrics, and frequency control  |d 1999  |g 53(2006), 7 vom: 29. Juli, Seite 1250-9  |w (DE-627)NLM098181017  |x 0885-3010  |7 nnns 
773 1 8 |g volume:53  |g year:2006  |g number:7  |g day:29  |g month:07  |g pages:1250-9 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_22 
912 |a GBV_ILN_24 
912 |a GBV_ILN_350 
951 |a AR 
952 |d 53  |j 2006  |e 7  |b 29  |c 07  |h 1250-9