Particle detachment during hydraulic shock loads in granular media filtration

Particle breakthrough can occur by either the breakoff of previously captured particles (or flocs) or the direct passage of some influent particles through the filter. Filtration experiments were performed in a laboratory-scale filter using spherical glass beads with a diameter of 0.55 mm as collect...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Water science and technology : a journal of the International Association on Water Pollution Research. - 1986. - 53(2006), 7 vom: 22., Seite 177-84
1. Verfasser: Kim, J K (VerfasserIn)
Weitere Verfasser: Lawler, D F
Format: Aufsatz
Sprache:English
Veröffentlicht: 2006
Zugriff auf das übergeordnete Werk:Water science and technology : a journal of the International Association on Water Pollution Research
Schlagworte:Journal Article Alum Compounds aluminum sulfate 34S289N54E
LEADER 01000caa a22002652 4500
001 NLM163306877
003 DE-627
005 20250207091423.0
007 tu
008 231223s2006 xx ||||| 00| ||eng c
028 5 2 |a pubmed25n0544.xml 
035 |a (DE-627)NLM163306877 
035 |a (NLM)16752779 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Kim, J K  |e verfasserin  |4 aut 
245 1 0 |a Particle detachment during hydraulic shock loads in granular media filtration 
264 1 |c 2006 
336 |a Text  |b txt  |2 rdacontent 
337 |a ohne Hilfsmittel zu benutzen  |b n  |2 rdamedia 
338 |a Band  |b nc  |2 rdacarrier 
500 |a Date Completed 06.10.2006 
500 |a Date Revised 17.09.2019 
500 |a published: Print 
500 |a Citation Status MEDLINE 
520 |a Particle breakthrough can occur by either the breakoff of previously captured particles (or flocs) or the direct passage of some influent particles through the filter. Filtration experiments were performed in a laboratory-scale filter using spherical glass beads with a diameter of 0.55 mm as collectors. A single type of particle suspension (Min-U-Sil 5) and three different destabilisation methods (pH control, alum and polymer destabilisation) were used to destabilise particles. The filtration velocity of 5 m/h was similar to that used in standard media filtration practice. To assess the possibility of particle detachment during normal filtration, a hydraulic shock load (20% increase of flow rate) was applied after 4 h of normal filtration. The magnitude of particle detachment was proportional to the particle size for non-Brownian particles. At the same time, less favourable particles, i.e. particles with larger surface charge, were easily detached during the hydraulic shock load. Therefore, proper particle destabilisation before filtration is crucial for maximum particle removal, as well as minimum particle breakthrough 
650 4 |a Journal Article 
650 7 |a Alum Compounds  |2 NLM 
650 7 |a aluminum sulfate  |2 NLM 
650 7 |a 34S289N54E  |2 NLM 
700 1 |a Lawler, D F  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Water science and technology : a journal of the International Association on Water Pollution Research  |d 1986  |g 53(2006), 7 vom: 22., Seite 177-84  |w (DE-627)NLM098149431  |x 0273-1223  |7 nnns 
773 1 8 |g volume:53  |g year:2006  |g number:7  |g day:22  |g pages:177-84 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_350 
951 |a AR 
952 |d 53  |j 2006  |e 7  |b 22  |h 177-84