High-pressure powder diffraction on synchrotron sources

The sample volume in diamond-anvil pressure cells suitable for X-ray powder diffraction studies is very small (</= 100 mum across). The resulting low signal-to-noise ratio has made it very difficult to obtain useful results with monochromatic angle-dispersive techniques, and the alternative white...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Journal of synchrotron radiation. - 1994. - 1(1994), Pt 1 vom: 01. Okt., Seite 69-73
1. Verfasser: Nelmes, R J (VerfasserIn)
Weitere Verfasser: McMahon, M I
Format: Aufsatz
Sprache:English
Veröffentlicht: 1994
Zugriff auf das übergeordnete Werk:Journal of synchrotron radiation
Schlagworte:Journal Article
LEADER 01000naa a22002652 4500
001 NLM163077274
003 DE-627
005 20231223095558.0
007 tu
008 231223s1994 xx ||||| 00| ||eng c
028 5 2 |a pubmed24n0544.xml 
035 |a (DE-627)NLM163077274 
035 |a (NLM)16728786 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Nelmes, R J  |e verfasserin  |4 aut 
245 1 0 |a High-pressure powder diffraction on synchrotron sources 
264 1 |c 1994 
336 |a Text  |b txt  |2 rdacontent 
337 |a ohne Hilfsmittel zu benutzen  |b n  |2 rdamedia 
338 |a Band  |b nc  |2 rdacarrier 
500 |a Date Completed 02.10.2012 
500 |a Date Revised 26.05.2006 
500 |a published: Print 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a The sample volume in diamond-anvil pressure cells suitable for X-ray powder diffraction studies is very small (</= 100 mum across). The resulting low signal-to-noise ratio has made it very difficult to obtain useful results with monochromatic angle-dispersive techniques, and the alternative white- beam energy-dispersive techniques have limited resolution and generally give unreliable peak intensities. The situation has been transformed recently by the introduction of the image-plate two-dimensional detector, which allows angle-dispersive methods to be used with a greatly increased signal and improved powder averaging. A short review is given of this development, the experimental techniques, and the principal advantages, particularly as found in results obtained at SRS Daresbury over the past two or three years 
650 4 |a Journal Article 
700 1 |a McMahon, M I  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Journal of synchrotron radiation  |d 1994  |g 1(1994), Pt 1 vom: 01. Okt., Seite 69-73  |w (DE-627)NLM09824129X  |x 1600-5775  |7 nnns 