Time differences between friedel reflections : accuracy of crystal setting and requirements on beam stability

In synchrotron radiation data collections where the wavelength is carefully set to optimize f''-derived crystallography intensity differences (Friedel pairs), careful alignment of the crystal is useful to minimize the time differences of stimulation of the reflections in the pairs. This pa...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Journal of synchrotron radiation. - 1994. - 2(1995), Pt 2 vom: 01. März, Seite 79-82
1. Verfasser: Nieh, Y P (VerfasserIn)
Weitere Verfasser: Helliwell, J R
Format: Aufsatz
Sprache:English
Veröffentlicht: 1995
Zugriff auf das übergeordnete Werk:Journal of synchrotron radiation
Schlagworte:Journal Article
LEADER 01000naa a22002652 4500
001 NLM16295249X
003 DE-627
005 20231223095319.0
007 tu
008 231223s1995 xx ||||| 00| ||eng c
028 5 2 |a pubmed24n0543.xml 
035 |a (DE-627)NLM16295249X 
035 |a (NLM)16714792 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Nieh, Y P  |e verfasserin  |4 aut 
245 1 0 |a Time differences between friedel reflections  |b accuracy of crystal setting and requirements on beam stability 
264 1 |c 1995 
336 |a Text  |b txt  |2 rdacontent 
337 |a ohne Hilfsmittel zu benutzen  |b n  |2 rdamedia 
338 |a Band  |b nc  |2 rdacarrier 
500 |a Date Completed 02.10.2012 
500 |a Date Revised 22.05.2006 
500 |a published: Print 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a In synchrotron radiation data collections where the wavelength is carefully set to optimize f''-derived crystallography intensity differences (Friedel pairs), careful alignment of the crystal is useful to minimize the time differences of stimulation of the reflections in the pairs. This paper quantifies these time differences as a function of crystal misorientation, with typical parameters, using the angular velocity of the crystal. Likewise, the time spent in the diffraction condition is also calculated via the angular reflecting range for a common synchrotron beam geometry. These times offer the user direct insight into the time-dependent aspects of the diffraction measurements. This therefore allows the optimum conditions to be set up so as to extract as accurate anomalous differences as possible in the context of synchrotron radiation beam stability and lifetime 
650 4 |a Journal Article 
700 1 |a Helliwell, J R  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Journal of synchrotron radiation  |d 1994  |g 2(1995), Pt 2 vom: 01. März, Seite 79-82  |w (DE-627)NLM09824129X  |x 1600-5775  |7 nnns 
773 1 8 |g volume:2  |g year:1995  |g number:Pt 2  |g day:01  |g month:03  |g pages:79-82 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_40 
912 |a GBV_ILN_350 
912 |a GBV_ILN_2005 
951 |a AR 
952 |d 2  |j 1995  |e Pt 2  |b 01  |c 03  |h 79-82