|
|
|
|
LEADER |
01000naa a22002652 4500 |
001 |
NLM162952406 |
003 |
DE-627 |
005 |
20231223095319.0 |
007 |
tu |
008 |
231223s1995 xx ||||| 00| ||eng c |
028 |
5 |
2 |
|a pubmed24n0543.xml
|
035 |
|
|
|a (DE-627)NLM162952406
|
035 |
|
|
|a (NLM)16714782
|
040 |
|
|
|a DE-627
|b ger
|c DE-627
|e rakwb
|
041 |
|
|
|a eng
|
100 |
1 |
|
|a Snell, E
|e verfasserin
|4 aut
|
245 |
1 |
0 |
|a Image-plate synchrotron laue data collection and subsequent structural analysis of a small test crystal of a nickel-containing aluminophosphate
|
264 |
|
1 |
|c 1995
|
336 |
|
|
|a Text
|b txt
|2 rdacontent
|
337 |
|
|
|a ohne Hilfsmittel zu benutzen
|b n
|2 rdamedia
|
338 |
|
|
|a Band
|b nc
|2 rdacarrier
|
500 |
|
|
|a Date Completed 02.10.2012
|
500 |
|
|
|a Date Revised 22.05.2006
|
500 |
|
|
|a published: Print
|
500 |
|
|
|a Citation Status PubMed-not-MEDLINE
|
520 |
|
|
|a Image plates have advantages over photographic films, which include wider dynamic range, higher detector quantum efficiency, reduced exposure time and large size. In this study, an on-line image-plate system has been used to record crystallographic data from a small crystal. In particular, synchrotron Laue data were recorded with lambda(min) = 0.455, lambda(max) = 1.180 A, in 20 images 10 degrees apart and with an exposure time of 0.3 s each from a crystal (0.02 x 0.05 x 0.25 mm) of a nickel-containing aluminophosphate, NiAPO. The Laue data were analyzed with the Daresbury Laue software, including the application of an absorption correction. The structure was solved by a combination of the Patterson method and successive difference Fourier calculations using SHELXS86 and SHELXL93; the final R value for 1934 unique reflections (all data) and 310 parameters was 7.90%. The structure agrees with that determined by monochromatic diffractometry using the same crystal and reported by Helliwell, Gallois, Kariuki, Kaucic & Helliwell [Acta Cryst. (1993), B49, 420-428] with an r.m.s. deviation of 0.03 A. Hence, this study shows the image-plate device to be very effective for synchrotron data collection and subsequent structure analysis from small crystals, i.e. 0.02 x 0.05 x 0.25 mm, in chemical crystallography as well as providing further confirmation of the practicability of Laue data in structure solution and refinement
|
650 |
|
4 |
|a Journal Article
|
700 |
1 |
|
|a Habash, J
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Helliwell, M
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Helliwell, J R
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Raftery, J
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Kaucic, V
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Campbell, J W
|e verfasserin
|4 aut
|
773 |
0 |
8 |
|i Enthalten in
|t Journal of synchrotron radiation
|d 1994
|g 2(1995), Pt 1 vom: 01. Jan., Seite 22-6
|w (DE-627)NLM09824129X
|x 1600-5775
|7 nnns
|
773 |
1 |
8 |
|g volume:2
|g year:1995
|g number:Pt 1
|g day:01
|g month:01
|g pages:22-6
|
912 |
|
|
|a GBV_USEFLAG_A
|
912 |
|
|
|a SYSFLAG_A
|
912 |
|
|
|a GBV_NLM
|
912 |
|
|
|a GBV_ILN_40
|
912 |
|
|
|a GBV_ILN_350
|
912 |
|
|
|a GBV_ILN_2005
|
951 |
|
|
|a AR
|
952 |
|
|
|d 2
|j 1995
|e Pt 1
|b 01
|c 01
|h 22-6
|