Feasibility and Realization of Single-Pulse Laue Diffraction on Macromolecular Crystals at ESRF

Laue diffraction patterns with an exposure time of ca 60 ps have been acquired at the European Synchrotron Radiation Facility (ESRF) on protein crystals by using the single-bunch mode of the storage ring. A 10 ns laser pulse initiating photodissociation was synchronized with the X-ray pulse. The pot...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Journal of synchrotron radiation. - 1994. - 3(1996), Pt 2 vom: 01. März, Seite 65-74
1. Verfasser: Bourgeois, D (VerfasserIn)
Weitere Verfasser: Ursby, T, Wulff, M, Pradervand, C, Legrand, A, Schildkamp, W, Labouré, S, Srajer, V, Teng, T Y, Roth, M, Moffat, K
Format: Aufsatz
Sprache:English
Veröffentlicht: 1996
Zugriff auf das übergeordnete Werk:Journal of synchrotron radiation
Schlagworte:Journal Article
LEADER 01000caa a22002652 4500
001 NLM162838301
003 DE-627
005 20250207081113.0
007 tu
008 231223s1996 xx ||||| 00| ||eng c
028 5 2 |a pubmed25n0543.xml 
035 |a (DE-627)NLM162838301 
035 |a (NLM)16702661 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Bourgeois, D  |e verfasserin  |4 aut 
245 1 0 |a Feasibility and Realization of Single-Pulse Laue Diffraction on Macromolecular Crystals at ESRF 
264 1 |c 1996 
336 |a Text  |b txt  |2 rdacontent 
337 |a ohne Hilfsmittel zu benutzen  |b n  |2 rdamedia 
338 |a Band  |b nc  |2 rdacarrier 
500 |a Date Completed 02.10.2012 
500 |a Date Revised 16.05.2006 
500 |a published: Print 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a Laue diffraction patterns with an exposure time of ca 60 ps have been acquired at the European Synchrotron Radiation Facility (ESRF) on protein crystals by using the single-bunch mode of the storage ring. A 10 ns laser pulse initiating photodissociation was synchronized with the X-ray pulse. The potential for a quantitative detection of conformational changes in proteins on the nanosecond timescale with this technique is demonstrated using the example of carbonmonoxymyoglobin, from simulations and real data. The instrumental aspects of the experiment (highly intense X-ray beam, fast shutter system, Laue camera, detector, laser apparatus and synchronization technique) are emphasized 
650 4 |a Journal Article 
700 1 |a Ursby, T  |e verfasserin  |4 aut 
700 1 |a Wulff, M  |e verfasserin  |4 aut 
700 1 |a Pradervand, C  |e verfasserin  |4 aut 
700 1 |a Legrand, A  |e verfasserin  |4 aut 
700 1 |a Schildkamp, W  |e verfasserin  |4 aut 
700 1 |a Labouré, S  |e verfasserin  |4 aut 
700 1 |a Srajer, V  |e verfasserin  |4 aut 
700 1 |a Teng, T Y  |e verfasserin  |4 aut 
700 1 |a Roth, M  |e verfasserin  |4 aut 
700 1 |a Moffat, K  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Journal of synchrotron radiation  |d 1994  |g 3(1996), Pt 2 vom: 01. März, Seite 65-74  |w (DE-627)NLM09824129X  |x 0909-0495  |7 nnns 
773 1 8 |g volume:3  |g year:1996  |g number:Pt 2  |g day:01  |g month:03  |g pages:65-74 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_40 
912 |a GBV_ILN_350 
912 |a GBV_ILN_2005 
951 |a AR 
952 |d 3  |j 1996  |e Pt 2  |b 01  |c 03  |h 65-74