Development of Synchrotron Radiation as a High-Intensity Source for X-ray Diffraction

Interest in the molecular mechanism of muscle contraction led to the search for an intense source of X-rays of 1-2 A wavelength so as to be able to examine the rich X-ray diffraction patterns given by muscles during contraction. This led to the first X-ray diffraction experiments using synchrotron r...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Journal of synchrotron radiation. - 1994. - 4(1997), Pt 6 vom: 01. Nov., Seite 366-79
1. Verfasser: Huxley, H E (VerfasserIn)
Weitere Verfasser: Holmes, K C
Format: Aufsatz
Sprache:English
Veröffentlicht: 1997
Zugriff auf das übergeordnete Werk:Journal of synchrotron radiation
Schlagworte:Journal Article
LEADER 01000naa a22002652 4500
001 NLM162806809
003 DE-627
005 20231223095013.0
007 tu
008 231223s1997 xx ||||| 00| ||eng c
028 5 2 |a pubmed24n0543.xml 
035 |a (DE-627)NLM162806809 
035 |a (NLM)16699251 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Huxley, H E  |e verfasserin  |4 aut 
245 1 0 |a Development of Synchrotron Radiation as a High-Intensity Source for X-ray Diffraction 
264 1 |c 1997 
336 |a Text  |b txt  |2 rdacontent 
337 |a ohne Hilfsmittel zu benutzen  |b n  |2 rdamedia 
338 |a Band  |b nc  |2 rdacarrier 
500 |a Date Completed 02.10.2012 
500 |a Date Revised 15.05.2006 
500 |a published: Print 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a Interest in the molecular mechanism of muscle contraction led to the search for an intense source of X-rays of 1-2 A wavelength so as to be able to examine the rich X-ray diffraction patterns given by muscles during contraction. This led to the first X-ray diffraction experiments using synchrotron radiation, carried out by Holmes, Rosenbaum and Witz at DESY, Hamburg, in September 1970. In the following years, the EMBL Outstation, to utilize synchrotron radiation for biological structure determination, was established at DESY and preliminary experiments on muscle were also carried out at NINA (Daresbury). The development of time-resolved techniques for muscle diffraction was first started in the MRC Molecular Biology Laboratory in Cambridge, using rotating-anode X-ray tubes, and was then greatly extended at the EMBL Outstation, Hamburg, using the storage ring DORIS. This was a very successful venture, and helped to drive the whole technology development and to interest other potential users in the technique 
650 4 |a Journal Article 
700 1 |a Holmes, K C  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Journal of synchrotron radiation  |d 1994  |g 4(1997), Pt 6 vom: 01. Nov., Seite 366-79  |w (DE-627)NLM09824129X  |x 1600-5775  |7 nnns 