Calibration and application of an X-ray image intensifier/ charge-coupled device detector for monochromatic macromolecular crystallography

Charge-coupled device (CCD)-based X-ray detectors allow data to be collected much more quickly (approximately 10 times) than with current on-line imaging-plate systems. At the ESRF, X-ray image intensifier/CCD detector systems have been developed. These have great potential as fast read-out detector...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Journal of synchrotron radiation. - 1994. - 4(1997), Pt 2 vom: 01. März, Seite 67-77
1. Verfasser: Hammersley, A P (VerfasserIn)
Weitere Verfasser: Brown, K, Burmeister, W, Claustre, L, Gonzalez, A, McSweeney, S, Mitchell, E, Moy, J P, Svensson, S O, Thompson, A W
Format: Aufsatz
Sprache:English
Veröffentlicht: 1997
Zugriff auf das übergeordnete Werk:Journal of synchrotron radiation
Schlagworte:Journal Article
LEADER 01000naa a22002652 4500
001 NLM16280640X
003 DE-627
005 20231223095012.0
007 tu
008 231223s1997 xx ||||| 00| ||eng c
028 5 2 |a pubmed24n0543.xml 
035 |a (DE-627)NLM16280640X 
035 |a (NLM)16699210 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Hammersley, A P  |e verfasserin  |4 aut 
245 1 0 |a Calibration and application of an X-ray image intensifier/ charge-coupled device detector for monochromatic macromolecular crystallography 
264 1 |c 1997 
336 |a Text  |b txt  |2 rdacontent 
337 |a ohne Hilfsmittel zu benutzen  |b n  |2 rdamedia 
338 |a Band  |b nc  |2 rdacarrier 
500 |a Date Completed 23.04.2008 
500 |a Date Revised 18.03.2022 
500 |a published: Print 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a Charge-coupled device (CCD)-based X-ray detectors allow data to be collected much more quickly (approximately 10 times) than with current on-line imaging-plate systems. At the ESRF, X-ray image intensifier/CCD detector systems have been developed. These have great potential as fast read-out detectors for macromolecular and other forms of crystallography. They are relatively large sensitive X-ray detectors but have two inherent weaknesses: convex detection surfaces leading to spatial distortion and non-uniformity of intensity response, and susceptibility to small changes in magnetic fields. A large improvement has been made to the accuracy obtained by non-uniformity of response calibration and correction, using fluorescence from doped lithium borate glasses. Monochromatic macromolecular crystallography demonstration experiments with external user groups have shown that high-quality results may be obtained under real experimental conditions 
650 4 |a Journal Article 
700 1 |a Brown, K  |e verfasserin  |4 aut 
700 1 |a Burmeister, W  |e verfasserin  |4 aut 
700 1 |a Claustre, L  |e verfasserin  |4 aut 
700 1 |a Gonzalez, A  |e verfasserin  |4 aut 
700 1 |a McSweeney, S  |e verfasserin  |4 aut 
700 1 |a Mitchell, E  |e verfasserin  |4 aut 
700 1 |a Moy, J P  |e verfasserin  |4 aut 
700 1 |a Svensson, S O  |e verfasserin  |4 aut 
700 1 |a Thompson, A W  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Journal of synchrotron radiation  |d 1994  |g 4(1997), Pt 2 vom: 01. März, Seite 67-77  |w (DE-627)NLM09824129X  |x 1600-5775  |7 nnns 
773 1 8 |g volume:4  |g year:1997  |g number:Pt 2  |g day:01  |g month:03  |g pages:67-77 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_40 
912 |a GBV_ILN_350 
912 |a GBV_ILN_2005 
951 |a AR 
952 |d 4  |j 1997  |e Pt 2  |b 01  |c 03  |h 67-77