The crystallography beamline I711 at MAX II

A new X-ray crystallographic beamline is operational at the MAX II synchrotron in Lund. The beamline has been in regular use since August 1998 and is used both for macro- and small molecule diffraction as well as powder diffraction experiments. The radiation source is a 1.8 T multipole wiggler. The...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Journal of synchrotron radiation. - 1994. - 7(2000), Pt 4 vom: 01. Juli, Seite 203-8
1. Verfasser: Cerenius, Y (VerfasserIn)
Weitere Verfasser: Ståhl, K, Svensson, L A, Ursby, T, Oskarsson, A, Albertsson, J, Liljas, A
Format: Aufsatz
Sprache:English
Veröffentlicht: 2000
Zugriff auf das übergeordnete Werk:Journal of synchrotron radiation
Schlagworte:Journal Article
LEADER 01000naa a22002652 4500
001 NLM161957471
003 DE-627
005 20231223093231.0
007 tu
008 231223s2000 xx ||||| 00| ||eng c
028 5 2 |a pubmed24n0540.xml 
035 |a (DE-627)NLM161957471 
035 |a (NLM)16609196 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Cerenius, Y  |e verfasserin  |4 aut 
245 1 4 |a The crystallography beamline I711 at MAX II 
264 1 |c 2000 
336 |a Text  |b txt  |2 rdacontent 
337 |a ohne Hilfsmittel zu benutzen  |b n  |2 rdamedia 
338 |a Band  |b nc  |2 rdacarrier 
500 |a Date Completed 16.05.2006 
500 |a Date Revised 12.04.2006 
500 |a published: Print-Electronic 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a A new X-ray crystallographic beamline is operational at the MAX II synchrotron in Lund. The beamline has been in regular use since August 1998 and is used both for macro- and small molecule diffraction as well as powder diffraction experiments. The radiation source is a 1.8 T multipole wiggler. The beam is focused vertically by a bendable mirror and horizontally by an asymmetrically cut Si(111) monochromator. The wavelength range is 0.8-1.55 A with a measured flux at 1 A of more than 10(11) photons s(-1) in 0.3 mm x 0.3 mm at the sample position. The station is currently equipped with a Mar345 imaging plate, a Bruker Smart 1000 area CCD detector and a Huber imaging-plate Guinier camera. An ADSC 210 area CCD detector is planned to be installed during 2000 
650 4 |a Journal Article 
700 1 |a Ståhl, K  |e verfasserin  |4 aut 
700 1 |a Svensson, L A  |e verfasserin  |4 aut 
700 1 |a Ursby, T  |e verfasserin  |4 aut 
700 1 |a Oskarsson, A  |e verfasserin  |4 aut 
700 1 |a Albertsson, J  |e verfasserin  |4 aut 
700 1 |a Liljas, A  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Journal of synchrotron radiation  |d 1994  |g 7(2000), Pt 4 vom: 01. Juli, Seite 203-8  |w (DE-627)NLM09824129X  |x 1600-5775  |7 nnns 
773 1 8 |g volume:7  |g year:2000  |g number:Pt 4  |g day:01  |g month:07  |g pages:203-8 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_40 
912 |a GBV_ILN_350 
912 |a GBV_ILN_2005 
951 |a AR 