Copper and zinc removal from roof runoff : from research to full-scale adsorber systems

Large, uncoated copper and zinc roofs cause environmental problems if their runoff is infiltrated into the underground or discharged into receiving waters. Since source control is not always feasible, barrier systems for efficient copper and zinc removal are recommended in Switzerland. During the la...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Water science and technology : a journal of the International Association on Water Pollution Research. - 1986. - 53(2006), 3 vom: 15., Seite 199-207
1. Verfasser: Steiner, M (VerfasserIn)
Weitere Verfasser: Boller, M
Format: Aufsatz
Sprache:English
Veröffentlicht: 2006
Zugriff auf das übergeordnete Werk:Water science and technology : a journal of the International Association on Water Pollution Research
Schlagworte:Journal Article Ferric Compounds Water 059QF0KO0R Copper 789U1901C5 Calcium Carbonate H0G9379FGK Zinc J41CSQ7QDS