Effect of critical dimension variation on SAW correlator energy
The effect of critical dimension (CD) variation and metallization ratio on the efficiency of energy conversion of a surface acoustic wave (SAW) correlator is examined. We find that a 10% variation in the width of finger electrodes predicts only a 1% decrease in the efficiency of energy conversion. F...
Veröffentlicht in: | IEEE transactions on ultrasonics, ferroelectrics, and frequency control. - 1999. - 53(2006), 2 vom: 01. Feb., Seite 497-501 |
---|---|
1. Verfasser: | |
Weitere Verfasser: | , , |
Format: | Aufsatz |
Sprache: | English |
Veröffentlicht: |
2006
|
Zugriff auf das übergeordnete Werk: | IEEE transactions on ultrasonics, ferroelectrics, and frequency control |
Schlagworte: | Evaluation Study Letter Research Support, U.S. Gov't, Non-P.H.S. |
Zusammenfassung: | The effect of critical dimension (CD) variation and metallization ratio on the efficiency of energy conversion of a surface acoustic wave (SAW) correlator is examined. We find that a 10% variation in the width of finger electrodes predicts only a 1% decrease in the efficiency of energy conversion. Furthermore, our model predicts that a metallization ratio of 0.74 represents an optimum value for energy extraction from the SAW by the interdigitated transducer (IDT) |
---|---|
Beschreibung: | Date Completed 31.03.2006 Date Revised 10.12.2019 published: Print Citation Status MEDLINE |
ISSN: | 0885-3010 |